Potentiometer; Motor; Wiring; Applying Power - Parker 506 Series Product Manual

Hide thumbs Also See for 506 Series:
Table of Contents

Advertisement

4-10
Installing the 506/507/508
Note: Even when intending to utilise tachogenerator feedback it may
be wise to initially run under armature control. Set feedback
voltage switches accordingly. Note that if this procedure is
followed the tachogenerator must be temporarily disconnected
as it will affect operation of the controller.

Potentiometer

(a)
(b)

Motor

(a)
(b)

Wiring

(a)
(b)

Applying Power

1.
Power on LED 1 should illuminate.
2.
Close "RUN" contact and apply a small speed setpoint (5%).
Armature current should now flow, the motor should turn and run at
a fixed speed.
If the motor runs above 5% up to top speed Open Run Contact.
If the controller is in "Armature" Control then excess speed is due to
incorrect setting of SW2 and 3, the speed scaling.
Product
P1 Ramp Up
P2 Ramp Down
P3 Stability
P4 I Limit
P5 IR Comp
P6 Min Speed
P7 Max Speed
External
Speed setpoint to minimum.
Check motor is compatible with controller and settings.
Check motor and load are free to rotate.
Check there is no loose wire ends on the PCB.
Check that there are no free wire ends on external controls
liable to contact grounded metal or earth (ground) referenced
parts.
www.comoso.com
Default
Anti-clockwise
Anti-clockwise
Mid
Anti-clockwise
Anti-clockwise
Anti-clockwise
Mid.
506/507/508 - HA389427