HP ProCurve 2910al Access Security Manual page 197

Hide thumbs Also See for ProCurve 2910al:
Table of Contents

Advertisement

Figure 5-12. Example of Configuring Accounting Types
Stop-Only:
Send a stop record accounting notice at the end of the accounting
session. The notice includes the latest data the switch has collected
for the requested accounting type (Network, Exec, Commands, or
System).
Do not wait for an acknowledgment.
The system option (page 5-40) always delivers stop-only operation because
the switch sends the accumulated data only when there is a reboot, reload,
or accounting on/off event.
Syntax: [no] aaa accounting < exec | network | system | commands > < start-stop
| stop-only > radius
Configures RADIUS accounting type and how data will be
sent to the RADIUS server.
For example, to configure RADIUS accounting on the switch with start-stop
for exec functions and stop-only for system functions:
RADIUS Authentication and Accounting
Configuring RADIUS Accounting
Configures exec and system
accounting and controls.
Summarizes the switch's
accounting configuration.
Exec and System accounting are
active. (Assumes the switch is
configured to access a reachable
5-41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents