Emc - Hirschmann BAT450-F User Manual

Installation industrial access point / client / access bridge
Hide thumbs Also See for BAT450-F:
Table of Contents

Advertisement

Parameter
UMTS
Band 1 (IMT 2100 12.2 kbit/s)
Band 8 (UMTS 900 12.2 kbit/s)
GSM / EDGE
EGSM 900 CS
Table 11: Conducted TX power tolerances
11.5

EMC

EMC interference
immunity
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EMC interference
emission
EN 55032
FCC 47 CFR Part 15
Installation BAT450-F
Release 06 08/2017
Conducted TX
(Transmit) power
tolerances
+23 dBm ± 1 dB
+32 dBm ± 1 dB
+27 dBm ± 1 dB
Electrostatic discharge
Contact discharge, test level 3
Air discharge, test level 3
Electromagnetic field
80 MHz ... 3000 MHz
3000 ... 6000 MHz
Fast transients (burst), test level 4
Power line
Data line
Voltage surges
Power line
Power line
Data line: test level 3
Conducted interference voltages, test level 3
150 kHz ... 80 MHz
Class B
Class B
Notes
Connectorized (Class 3)
GMSK mode, connectorized
(Class 4; 2 W, 33 dBm)
8PSK mode, connectorized
(Class E2; 0.5 W, 27 dBm)
line/line
line/ground
6 kV
8 kV
20 V/m
3 V/m
2 kV
4 kV
1 kV
2 kV
2 kV
10 V
55