11 Technical data

11.1

General technical data

Dimensions
BAT450-F
W × H × D
Weight
Supply voltage
Power supply via an 8-pin, "X"-coded M12 socket for PoE port or a 5-pin,
"A"-coded M12 plug
Nominal voltage DC
Voltage range DC incl.
maximum tolerances
Connection type
Power loss buffer
Overload current protection at
input
Back-up fuse
Peak inrush current
Climatic
Minimum clearance around the
conditions during
device
operation
Ambient air temperature
Humidity
Air pressure
Climatic
Ambient air temperature
conditions during
Humidity
storage
Air pressure
Pollution degree
Protection classes Laser protection
Degree of protection
a. Temperature of the ambient air at a distance of 2 in (5 cm) from the device
44
See "Dimension drawings" on page 45.
≥ 2.0 kg
(depending on the device variant)
24 V
16.8 V ... 32 V
M12 plug
Tightening torque of
the locking screw
10 ms at 19.2 V DC
Non-replaceable fuse
Nominal rating:
Characteristic:
14 A
Top and bottom device side: 3.94 in (10 cm)
Left and right device side: 0.79 in (2 cm)
a
−40 °F ... +158 °F (−40 °C ... +70 °C)
10 % ... 95 % (non-condensing)
minimum 700 hPa (+9842 ft; +3000 m)
maximum 1060 hPa (−1312 ft; −400 m)
a
−40 °F ... +185 °F (−40 °C ... +85 °C)
10 % ... 95 % (non-condensing)
minimum 700 hPa (+9842 ft; +3000 m)
maximum 1060 hPa (−1312 ft; −400 m)
2
Class 1 in compliance with IEC 60825-1
IP65/67
5.3 lb-in (0.6 Nm)
3.5 A
slow blow
Installation BAT450-F
Release 06 08/2017