Hirschmann BAT450-F User Manual

Industrial access point / client / access bridge
Hide thumbs Also See for BAT450-F:

Advertisement

Quick Links

User Manual
Installation
Industrial Access Point / Client / Access Bridge
BAT450-F
Installation BAT450-F
Technical support
Release 03 08/2016
https://hirschmann-support.belden.eu.com

Advertisement

Table of Contents
loading

Summary of Contents for Hirschmann BAT450-F

  • Page 1 User Manual Installation Industrial Access Point / Client / Access Bridge BAT450-F Installation BAT450-F Technical support Release 03 08/2016 https://hirschmann-support.belden.eu.com...
  • Page 2 In addition, we refer to the conditions of use specified in the license contract. You can get the latest version of this manual on the Internet at the Hirschmann product site (www.hirschmann.com). Hirschmann Automation and Control GmbH Stuttgarter Str.
  • Page 3: Table Of Contents

    2.2.2 Installing the device on a pole 2.2.3 Grounding the device Installing the antennas Connecting the power supply Operating the device 2.5.1 Connect the power supply 2.5.2 Defining IP parameters 2.5.3 Defining WLAN basic settings 2.5.4 Configuring the transmit power Installation BAT450-F Release 03 08/2016...
  • Page 4 Monitoring the ambient air temperature Maintenance and service Disassembly Technical data Further Support Installation BAT450-F Release 03 08/2016...
  • Page 5: Safety Instructions

    Certified usage   Use the product only for the application cases described in the Hirschmann product information, including this manual.  Operate the product only according to the technical specifications. See “Technical data” on page 33.  Connect to the product only components suitable for the requirements of the specific application case.
  • Page 6 The cables used are permitted for the temperature range of the application case.  Relevant for North America: The power cords are suitable for ambient air temperatures of at least 167 °F (75 °C). The power cord wires are made of copper. Installation BAT450-F Release 03 08/2016...
  • Page 7  The power supply cable is suitable for the voltage, the current and the physical load. Hirschmann recommends a wire diameter of at least 0.75 mm² (AWG18). The following requirements apply alternatively: Alternative 1 The power supply complies with the requirements for a limited power source (LPS) as per EN 60950-1.
  • Page 8 In accordance with the above-named EU directive(s), the EU conformity declaration will be available to the relevant authorities at the following address: Hirschmann Automation and Control GmbH Stuttgarter Str. 45-51 72654 Neckartenzlingen Germany Tel.: +49 1805 141538...
  • Page 9  Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by the holder of the certificate could void the user’s authority to operate this equipment. Installation BAT450-F Release 03 08/2016...
  • Page 10 5.15 GHz ... 5.725 GHz ... 5.25 GHz band 5.825 GHz band BAT-ANT-RSMA-2AGN-R BAT-ANT-N-3AGN-IP67 BAT-ANT-N-MiMoDB-5N-IP65 BAT-ANT-N-MiMo5-9N-IP65 BAT-ANT-N-8G-DS-IP65 The use of antennas missing in this list is strictly prohibited. The required antenna impedance is 50 ohms. Installation BAT450-F Release 03 08/2016...
  • Page 11 18 dBi: Antennas operating with this device Permitted band of operation model: 2.4 GHz band 5.15 GHz ... 5.725 GHz ... 5.25 GHz band 5.825 GHz band BAT-ANT-RSMA-2AGN-R BAT-ANT-N-3AGN-IP67 BAT-ANT-N-MiMoDB-5N-IP65 BAT-ANT-N-MiMo5-9N-IP65 BAT-ANT-N-8G-DS-IP65 BAT-ANT-N-MiMo-18N-IP65 Installation BAT450-F Release 03 08/2016...
  • Page 12  Connect the BAT-ANT-N-MiMo-18N-IP65 in this way exclusively. Differing connection configurations are illegal. Recycling note  After usage, this device must be disposed of properly as electronic waste, in accordance with the current disposal regulations of your county, state, and country. Installation BAT450-F Release 03 08/2016...
  • Page 13: About This Manual

    Documentation mentioned in the “User Manual Installation” that is not supplied with your device as a printout can be found as PDF files for downloading on the Internet on the Hirschmann product pages (www.hirschmann.com). Legend The symbols used in this manual have the following meanings: ...
  • Page 14: Description

    The characteristic values stand for specific product properties. Item Characteristic Character Description istic value 1 ... 8 Product BAT450-F IP65/67 housing 9 ... 10 Country approvals Australia Europe (CE) United Arab Emirates United States/Canada (FCC/IC) Slot 1 WLAN module...
  • Page 15 Software option 1 VPN-5 VPN-50 VPN-100 Not present Software option 2 Not present Software option 3 Public Spot AutoWDS Not present Configuration Accessory package Not present Device model Hirschmann standard Table 1: Device name and product code Installation BAT450-F Release 03 08/2016...
  • Page 16: Device Views

    Supply voltage connection via 5-pin, A-coded M12 plug Ethernet port 1 8-pin, X-coded M12 plug for 10/100/1000 Mbit/s PoE port Optional: 8-pin, X-coded M12 plug for 10/100/1000 Mbit/s Ethernet port 2 twisted-pair port V.24/ACA11 4-pin, A-coded M12 socket Connection for functional ground Installation BAT450-F Release 03 08/2016...
  • Page 17: Power Supply

    1000 Mbit/s full duplex  Power over Ethernet The socket housing is electrically connected with the device housing. Delivery state: Autonegotiation activated The PoE power is supplied via the wire pairs transmitting the signal (phantom voltage). Installation BAT450-F Release 03 08/2016...
  • Page 18: 10/100/1000 Mbit/S Twisted Pair Port

    After the working voltage is set up, the software starts and initializes itself. Afterwards, the device performs a self-test. During this process, various LEDs light up. 1.6.1 Device state These LEDs provide information about conditions which affect the operation of the whole device. Installation BAT450-F Release 03 08/2016...
  • Page 19: Management Interfaces 1.7.1 V.24 Interface (External Management)

    Lights up 1 Ethernet connection active green/yello flashing Device is transmitting and/or receiving data Yellow Lights up 2 Ethernet connections active Management interfaces 1.7.1 V.24 interface (external management) This interface is a 4-pin, A-coded M12 socket. Installation BAT450-F Release 03 08/2016...
  • Page 20 The V.24 interface is not electrically isolated from the supply voltage. You can use the V.24 interface to connect the AutoConfiguration Adapter ACA11 storage medium. The AutoConfiguration Adapter ACA21-M12 storage medium is incompatible with BAT450-F. Figure Function Transmit Data Receive Data N.C.
  • Page 21: Reset Button

    You have the option of loading a customer-specific configuration saved on the device as an alternative to the default configuration. You will find more information in the “Configuration Guidelines User Manual”, in the chapter “Using the Boot Configurations”. Installation BAT450-F Release 03 08/2016...
  • Page 22: Installation

    Connecting the power supply  Operating the device Checking the package contents  Check whether the package includes all items named in the section “Scope of delivery” on page  Check the individual parts for transport damage. Installation BAT450-F Release 03 08/2016...
  • Page 23: Installing And Grounding The Device

    Proceed as follows:  Prepare the assembly at the installation site. See “Dimension drawings” on page 34.  Install the device with suitable fastening components.  Seal all unused connections and ports with protection screws. Installation BAT450-F Release 03 08/2016...
  • Page 24: Installing The Device On A Pole

    2.2.2 Installing the device on a pole The devices are suitable for pole mounting with the additional BAT450-F pole mounting set (see on page 43 “Accessories”). The BAT450-F pole mounting set with enclosed U-bolts is designed for the following pole diameter range: ...
  • Page 25: Grounding The Device

    Start connecting the electrical wires only if all the above safety requirements are fulfilled. See “Requirements for connecting electrical wires” on page 6. Failure to follow these instructions can result in death, serious injury, or equipment damage. Installation BAT450-F Release 03 08/2016...
  • Page 26: Operating The Device

     Connect the data cables according to your requirements. 5-pin M12 plug, A-encoded   Connect the data cables according to your requirements.  Plug the socket into the M12 plug on the device.  Enable the supply voltage. Installation BAT450-F Release 03 08/2016...
  • Page 27: Defining Ip Parameters

    If you are using an E-certified device in a vehicle and are driving the vehicle within the EU, set the country profile for Germany. This country profile is identical to all the country profiles for EU.  Click the “Set” button. Installation BAT450-F Release 03 08/2016...
  • Page 28  Subtract the cable and installed overvoltage protector attenuation from the antenna gain. Enter the calculated value in the “Antenna gain” field.  Click the “Set” button to save the value. Installation BAT450-F Release 03 08/2016...
  • Page 29 Installation BAT450-F Release 03 08/2016...
  • Page 30 It is higher than the ambient air temperature. The maximum internal temperature of the device named in the technical data is a guideline that indicates to you that the maximum ambient air temperature has possibly been exceeded. Installation BAT450-F Release 03 08/2016...
  • Page 31 Maintenance and service  When designing this device, Hirschmann largely avoided using high-wear parts. The parts subject to wear and tear are dimensioned to last longer than the lifetime of the product when it is operated normally. Operate this device according to the specifications.
  • Page 32 Disassembly  Disconnect the data cables.  Disable the supply voltage.  Disconnect the power supply cable.  Remove the antennas.  Disconnect the grounding. Installation BAT450-F Release 03 08/2016...
  • Page 33 1060 hPa (−1312 ft; −400 m) Pollution degree Protection classes Laser protection Class 1 in compliance with IEC 60825-1 Degree of protection IP65/67 a. Temperature of the ambient air at a distance of 2 inches (5 cm) from the device Installation BAT450-F Release 03 08/2016...
  • Page 34 Support of 2.4 GHz and 5 GHz: 2400 MHz to 2483.5 MHz (ISM) and 5170 MHz to 5850 MHz Modulation technology  22M 0F7D (DSSS/OFDM) at 2.4 GHz  5 MHz (ISM) and 5170-5850 MHz Installation BAT450-F Release 03 08/2016...
  • Page 35 12 Mbps 22 dBm −90 dBm 18 Mbps 22 dBm −89 dBm 24 Mbps 22 dBm −85 dBm 36 Mbps 21 dBm −82 dBm 48 Mbps 20 dBm −78 dBm 54 Mbps 19 dBm −77 dBm Installation BAT450-F Release 03 08/2016...
  • Page 36 Typical transmit power Typical receive sensitivity MCS0 17 dBm −92 dBm MCS1 17 dBm −91 dBm MCS2 17 dBm −89 dBm MCS3 17 dBm −84 dBm MCS4 17 dBm −81 dBm MCS5 15 dBm −77 dBm Installation BAT450-F Release 03 08/2016...
  • Page 37 IEEE 802.11a Data rate Typical transmit power Typical receive sensitivity 6Mbps 10 dBm -93 dBm 9Mbps 10 dBm -93 dBm 12Mbps 10 dBm -93 dBm 18Mbps 10 dBm -91 dBm 24Mbps 10 dBm -88 dBm Installation BAT450-F Release 03 08/2016...
  • Page 38 MCS6 16 dBm -73 dBm MCS7 15 dBm -72 dBm MCS8 22 dBm -87 dBm MCS9 21 dBm -90 dBm MCS10 22 dBm -86 dBm MCS11 21 dBm -82 dBm MCS12 16 dBm -79 dBm Installation BAT450-F Release 03 08/2016...
  • Page 39 MCS11 7 dBm -84 dBm MCS12 5 dBm -81 dBm MCS13 2 dBm -77 dBm MCS14 2 dBm -75 dBm MCS15 1 dBm -73 dBm MCS16 8 dBm -92 dBm MCS17 8 dBm -91 dBm Installation BAT450-F Release 03 08/2016...
  • Page 40 Class B FCC 47 CFR Part 15 Class B Stability Vibration IEC 60068-2-6 Test FC test level according to IEC 61131-2 Shock IEC 60068-2-27 Test Ea test level in accordance with IEC 61131-2, EN 50155 Installation BAT450-F Release 03 08/2016...
  • Page 41 Length of a twisted pair segment max. 100 m (for cat5e cable) Power consumption/power output  Device Power consumption Power output BAT450-F 1 × WLAN module 9.95 W 33.35 2 × WLAN module 12.95 W 44.19 Installation BAT450-F Release 03 08/2016...
  • Page 42 Scope of delivery  Number Article 1 × WLAN module 2 × WLAN module 1 × Device 1 × General safety instructions 1 ×, 2 × or 3 × Protection cap (M12, plastic) for Ethernet port 1, Ethernet port 2 or V.24 interface premounted 1 ×...
  • Page 43 942-110-001 (10 pieces) 50 Ω terminators for closing free antenna connections 942-118-001 (10 pieces) BAT450-F pole For fastening the devices to pole for the following 943 966-001 mounting set pole diameter range: 1.46 in ... 2.56 in (37 mm ... 65 mm) Note: Products recommended as accessories may have characteristics that do not fully correspond to those of the corresponding product.
  • Page 44 If your device has a shipping approval according to Germanischer Lloyd, you find the approval mark printed on the device label. You will find out whether your device has other shipping approvals on the Hirschmann website under www.hirschmann.com in the product information.
  • Page 45 Further Support Technical Questions  For technical questions, please contact any Hirschmann dealer in your area or Hirschmann directly. You will find the addresses of our partners on the Internet at http://www.hirschmann.com. A list of local telephone numbers and email addresses for technical support directly from Hirschmann is available at https://hirschmann-support.belden.eu.com.

Table of Contents