11.4.4

Conducted RX sensitivity (UMTS Bands)

UMTS Bands
Band 1
0.1% BER
(UMTS 2100)
12.2 kbit/s
Band 8
0.1% BER
(UMTS 900)
12.2 kbit/s
Table 9:
Conducted RX sensitivity (UMTS Bands)
a. Per 3GPP specification
11.4.5

Conducted RX sensitivity (GSM/EDGE Bands)

GSM/EDGE
Bands
EGSM 900
2% BER
10% BLER
DCS 1800
2% BER
10% BLER
Table 10: Conducted RX sensitivity (GSM/EDGE Bands)
a. Per 3GPP specification
b. CS = Circuit Switched
c. CS = Circuit Switched
11.4.6

Conducted TX power tolerances

Parameter
LTE
LTE Band 1, 3, 8, 20
LTE Band 7
Table 11: Conducted TX power tolerances
54
Conducted RX (Receive) sensitivity
(dBm)
Primary
Secondary
(Typical)
(Typical)
−111.4
−109.8
−111.8
−111.0
Conducted RX (Receive)
sensitivity (dBm)
Typical
b
CS
−109
GMSK (CS1) −112
EDGE
−104
(MCS5)
c
CS
−109
GMSK (CS1) −112
EDGE
−104
(MCS5)
Conducted TX
(Transmit) power
tolerances
+23 dBm ± 1 dB
+22 dBm ± 1 dB
Primary /
a
Secondary
(Worst
Case)
−106.7
−103.7
a
Worst case
−102
−104
−98
−102
−104
−98
Notes
Can vary as per the MPR
(Maximum Power Reduction) table
in the 3GPP TS_136101
specification