Top Vent - Horizontal Termination con't.
Note: For every 1 ft. of vertical drop the total
allowable length must be reduced by 2 ft.
NOTICE: If pipe configuration includes a vertical component that goes
downward, a vertical component going back upward is not allowed.
WARNING! Risk of Fire! Minimum 2 ft. straight vertical DVP pipe directly off appliance followed by 90 degree elbow and
DVP-2SL adapter on these models:
ESCAPE-42DV, ESCAPE-36DV, ESC-42ST, HEIR36, HEIR42, HEIR50, LUX36, LUX42, TRUE-36, TRUE-42, TRUE-
50, CERONA-36, CERONA-42, MEZZO36, MEZZO36ST, MEZZO48, MEZZO48ST, CRAVE4836, CRAVE4836ST,
CRAVE6048, CRAVE6048ST, CRAVE7260, CRAVE7260ST, CRAVE8472, CRAVE8472ST, MEZZO60, MEZZO60ST,
MEZZO72, MEZZO72ST, MARQ36IN, MARQ42IN, MARQ42STIN, ECHEL36IN, ECEL36STIN, ECHEL48IN, ECH-
EL48STIN, ECHEL60IN, ECHEL72IN, ODFORTG-36, ODMEZG-36
Combustibles surrounding pipe may overheat.
Minimum Vent Run
A minimum of 2 ft. of vertical piping is
required between the appliance and the
PVLP-SLP with certain appliance mod-
els. See Table 2.1.
Figure 2.3 Horizontal PVLP Orientation
8
Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP) Instructions • 4052-900 Rev. M• 09/17
V
2
H
2
Maximum Vent Run
See Chart in Section 2.C: "Venting Length - Model Categories and
Length Requirements by Termination Type."
H
1
A DVP-2SL or DVP-SLP24
is required in any position
after the first 90 degree
elbow on certain models.
See Table 2.1.
V
1