Installation Steps:
If the appliance is equipped with an IFT-ACM, proceed to
step 10. If not, proceed to next step.
5. Locate the IntelliFire™ Touch electronic control module
(IFT-ECM) in the control cavity of the appliance and
move the three-position switch to the OFF position.
See Figure 4.7.
6. Remove protective rubber cap from connector on the
top of the IFT-ECM. See Figure 4.7.
Figure 4.7. IFT-ECM
7. Attach velcro included with the IFT-ACM to the bottom
of the ACM. See Figure 4.8.
8. Connect the IFT-ACM to the IFT-ECM by aligning the
pins and tabs and pushing the IFT-ACM into the IFT-
ECM until both tabs latch in place. Ensure the IFT-
ECM and IFT-ACM are aligned with each other and
fastened securely. See Figure 4.8.
Figure 4.8. Connecting IFT-ACM and IFT-ECM
WARNING! Risk of Shock! DO NOT touch male pins.
Leave rubber cap on all ports unless port is being con-
nected to a load.
25
Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP) Instructions • 4052-900 Rev. M• 09/17
ATTACH VELCRO
LIGHTS
Figure 4.9. Fan, Lights and Power Vent Connection
9. The IFT-ACM can provide power to HHT approved
options including fan, lights and power vent.
To connect a fan kit to the IFT-ACM, insert the
three prong male plug from the fan into the re-
ceptacle located on the right side of the IFT-ACM.
See Figure 4.9.
To connect a light kit to the IFT-ACM, remove pro-
tective rubber cap labeled 'LIGHTS' and connect
to the female cord that was supplied in your lights
kit into the three male pins on the IFT-ACM. See
Figure 4.9.
To connect a power vent kit to the IFT-ACM, re-
move protective rubber cap labeled 'AUX' and
connect to the female cord of the PVI-WH wire
harness into the three male pins on the IFT-ACM.
See Figure 4.9.
WARNING! Risk of Shock! DO NOT touch male pins.
Leave rubber cap on all ports unless port is being con-
nected to a lead.
Note:
It will be necessary to re-pair the remote
after installing HHT approved options to the appliance.
Refer to Section 4C for pairing the remote.
10. Refer to wiring diagram with Power Vent to make re-
maining connections. See Figure 4.10.
POWER CORD
FAN
POWER
VENT