INSTALLATION
The type of control used to power the appliance is the
determining factor in making the appliance compatible
with the PVLP-SLP.
• A 7/8 in. diameter hole must be bored in the side of
the fireplace outer wrap in which the 5 wires from the
power vent will be routed. The hole should be located
2 inches to the side of the junction box and 4-inches
up from the base of the fireplace.
TO JUNCTION BOX 110VAC
VALVE
Figure 4.3 PVLP Wiring for IntelliFire™ Plus RC100, RC200, RC300 Controls
20
Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP) Instructions • 4052-900 Rev. M• 09/17
STEP 1
8K1-PVI
STEP 5
STEP 7
8K1-PVI
WIRE HARNESS
GROUND
IntelliFire™ Plus IPI Module (Black)
1. Attach the new 8K1-PVI module to the 6V transformer.
2. Connect the pilot wires (white to S and orange to I) to
the 8K1-PVI module.
3. Connect the new Aux RC300 to the 8K1-PVI module.
4. Plug the Aux RC300 into the Junction Box.
5. Attach the 8K1-PVI wire harness to the 8K1-PVI
module. Connect green and orange valve wires and
reconnect ground wire to chassis.
6. Connect the accessory cable coming from the
PVLP-SLP to the AUX RC300 (AUX 2 port) and the
corresponding colored wire on the wire harness.
7. Connect the stepper motor wires to the 8K1-PVI
module.
STEP 2
AUX RC300
ORG
MODULE
WHT
STEP 3
STEP 6
BROWN
RED
STEP 4
TO JUNCTION BOX
110VAC
ACCESSORY CABLE