SECURE TO BUILDING EXTERIOR
USING TOP (2) AND BOTTOM (2)
MOUNTING HOLES
Figure 3.22 SLP-LPC Attached to LPC-BEK
SILICONE (with a minimum of 300°F
continuous exposure rating)
(ALL 4 SIDES)
SILICONE (with a
minimum of 300°F
continuous exposure
rating)
(ALL 4 SIDES)
FINISHING MATERIAL
5 IN. MAXIMUM
Figure 3.23 Silicone Weather Sealing
19. Apply a bead of silicone (with a minimum of 300° F
continuous exposure rating) around the entire metal
flange of the PVLP-SLP. See Figure 3.24. Align with
PVLP-BEK as shown in Figure 3.22. Ensure cap is
level and square, then secure PVLP-SLP to PVLP-BEK
as shown in Figure 3.23.
20. After the PVLP-SLP has been secured to the PVLP-
BEK, silicone (with a minimum of 300° F continuous
exposure rating) should be applied around outer edge
of PVLP-BEK where it meets the building exterior.
Silicone (with a minimum of 300° F continuous
exposure rating) should also be applied where PVLP-
SLP and PVLP-BEK meet, as shown in Figure 3.23.
17
Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP) Instructions • 4052-900 Rev. M• 09/17
21. Place decorative cover onto cap and fasten. Once
cover has been secured, installation is complete.
22. Place a bead of silicone (with a minimum of 300° F
continuous exposure rating) on the back side of the
mounting flange for the cap. See Figure 3.24.
23. Install the cap into the wall and attach the cap to the
wall using the eight screws provided. See Figure 3.25.
NOTE: Be careful not to tear the gasket on the mounting
flange.
24. Once the cap is fastened to the wall, apply a bead of
silicone around the cap base. See Figure 3.26.
25. Reinstall the cap cover using the four scews removed
earlier.
Figure 3.24
Figure 3.25
Figure 3.26