Hearth and Home Technologies PVLP-SLP Installation Instructions Manual page 21

Power vent low profile
Table of Contents

Advertisement

IntelliFire™ IPI Module (Green)
1. Attach the new 8K1-PVI module to the 6V transformer.
2. Connect the pilot wires (white to S and orange to I) to
the 8K1-PVI module.
3. Connect the new Aux RC300 to the 8K1-PVI module.
4. Plug the Aux RC300 into the Junction Box.
5. Attach the 8K1-PVI wire harness to the 8K1-PVI
module. Connect green and orange valve wires and
reconnect ground wire to chassis.
6. Connect the accessory cable coming from the
PVLP-SLP to the AUX RC300 (AUX 2 port) and the
corresponding colored wire on the wire harness.
STEP 1
TO JUNCTION BOX 110VAC
ORANGE
VALVE
(PILOT)
GREEN
(MAIN)
Figure 4.4 PVLP Wiring for Intellifire™ IPI Module
21
Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP) Instructions • 4052-900 Rev. M• 09/17
STEP 2
8K1-PVI
ORG
WHT
STEP 5
8K1-PVI
WIRE HARNESS
BROWN
RED
GROUND
AUX RC300
MODULE
STEP 3
STEP 6
ACCESSORY CABLE
STEP 4
TO JUNCTION BOX
110VAC

Advertisement

Table of Contents
loading

Table of Contents