Electrical Information; Controls - Hearth and Home Technologies PVLP-SLP Installation Instructions Manual

Power vent low profile
Table of Contents

Advertisement

4

Electrical Information

A. Wiring the Appliance for the PVLP-SLP
with IntelliFire™ and IntelliFire™ Plus
(IPI) Controls
NOTICE: The 8K1-PVI control module must be used to
integrate the PVLP-SLP to the fireplace. (The 8K1-PVI is
included with the PV-IPI-CK which is sold separately. When
installing the PVLP-SLP on PRIMO models the 8K1-PVI is
included with the fireplace.)
NOTICE: Electrical wiring must be done in accordance
with national, provincial, and/or local electric codes.
CAUTION! Risk of shock! Disconnect electrical power
from fireplace/power vent before performing any mainte-
nance, repair, or electrical wiring.
NOTICE: Electrical service of 120 VAC-60Hz must be
supplied to the junction box of the fireplace in order for the
power vent to operate correctly.
TO JUNCTION
BOX (110V)
Figure 4.1 IntelliFire Plus™ (Black) IPI Module Wiring as Shipped from Factory
18
Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP) Instructions • 4052-900 Rev. M• 09/17
STEP 4
MODULE
STEP 1
STEP 3
STEP 7
REMOVAL OF UNNECESSARY PARTS
Refer to the appropriate directions depending on the color
of the IPI module (Black or Green.)
IntelliFire Plus™ IPI Module (Black)
Refer to Figure 4.1 for steps 1 through 7. The shaded
portion corresponding to the numbered step is the task to
be performed.
1. Unplug control module power.
2. Detach the white and orange wires from the control
module.
3. Detach the remaining harnesses from the control mod-
ule.
4. Remove the black control module. This will no longer
be needed.
5. Remove and discard battery pack (if present).
6. Unplug wall switch wires (if present).
7. Remove and discard IPI wire harness.
NOTICE: When installing the power vent with
FLAME
the MEZZO, ECHELON and CRAVE models,
IGNITER
SENSE
the LED will need to be disconnected from the
AUX2 (factory setting) and moved to AUX1.
Plug the power vent system into AUX2. The
LED function will only be operational on the
HIGH setting.
STEP 2
STEP 5
BATTERY PACK
6V DC (AA X 4)
THERMOSTAT WIRE
ASSEMBLY / WALL
SWITCH WIRE
STEP 6

Advertisement

Table of Contents
loading

Table of Contents