Note: PVLP-SLP requires special control system
configurations:
For IntelliFire™ and IntelliFire™ Plus models, a
RC100, RC200 or RC300 and PV-IPI-CK control
system is required for installation (except on PRIMO
models). The PV-IPI-CK is sold separately.
For IntelliFire™ Touch models, an IFT-ACM and IFT-
RC400 is required for installation. The IFT-ACM and
IFT-RC400 may need to be purchased separately if
the appliance is not already equipped with IFT.
The battery-backup feature cannot be used with
models configured with the PVLP-SLP.
The wired wall switch feature cannot be used with
models configured with the PVLP-SLP.
An appliance with PVLP-SLP installed cannot be
operated with battery-backup or a wired wall switch.
Note: The battery back-up and wired wall switch feature
of any IPI system are removed when the PVLP-SLP
power vent is installed. The fireplace may no longer be
operated with battery back-up and/or a wired wall switch.
The PVLP-SLP operates on 120VAC, 60Hz electrical
service which is supplied at the fireplace junction box.
A. Components and Service Parts List
Service Parts List
Replacement parts can be obtained from your dealer. Re-
pair of the Power Vent should only be done by a qualified
service technician.
BLOWER ASSEMBLY
4052-796
NOTE: Wire Harness connecting PVI to appliance sold separately.
NOTE: Wire Harness connecting PVLP-SLP to appliance sold separately. The length of wire harness needed varies by
installation. For all appliances equipped with IntelliFire™ or IntelliFire™ Plus ignition, other than the PRIMO, PV-IPI-CK con-
The length of wire harness needed varies by installation.
version kit and one of the following; RC100, RC200 or RC300 are required. This kit includes all components to install the
For all appliances other than the premium linear models a PVLP-CK
PVLP-SLP to IntelliFire™ or IntelliFire™ Plus appliances. For appliances equipped with IntelliFire™ Touch (IFT) controls, an
conversion kit is required. This kit includes all components to install
IFT-RC400 remote and an IFT-ACM are required on the appliance.
the PVLP-SLP.
Figure 1.1 Service Parts
2
Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP) Instructions • 4052-900 Rev. M• 09/17
VACUUM SWITCH
4052-840
IMPORTANT OPERATIONAL NOTE:
being used to run the fireplace is activated, a 120 seconds
delay will occur before pilot ignition will begin. This is to allow
a pre-purge by the PVLP-SLP. If, after 135 seconds, the pilot
and burner do not light, refer to the Troubleshooting section
of this instruction for further direction. There will also be a
20-minute post-purge in which the PVLP-SLP will continue to
run after appliance is turned off.
NOTICE: The blower motors present in this power vent
will generate sound during operation. The effects of the
increased sound level can be minimized with careful plan-
ning during installation of the system.
Required Wire Harness
Lengths Available
10 ft. PV Wire Harness
20 ft. PV Wire Harness
40 ft. PV Wire Harness
60 ft. PV Wire Harness
80 ft. PV Wire Harness
100 ft. PV Wire Harness
When the control
Part Number
PVI-WH10
PVI-WH20
PVI-WH40
PVI-WH60
PVI-WH80
PVI-WH100