B. Wiring the Appliance for the PVLP-SLP
with IntelliFire™ Touch (IFT) Controls
NOTICE: When integrating the PVLP-SLP onto an ap-
pliance with IntelliFire™ Touch (IFT) controls, the RC400
remote control and the Auxiliary Control Module (IFT-ACM)
must be equipped on the appliance. The IFT-RC400
includes the RC400 and the IFT-ACM. The IFT-ACM is
available separtely for appliances already equipped with
the RC400 remote control.
NOTICE: Electrical wiring must be done in accordance
with national, provincial, and/or local electric codes.
CAUTION! Risk of shock! Disconnect electrical power
from fireplace/power vent before performing any mainte-
nance, repair, or electrical wiring.
NOTICE: Electrical service of 120 VAC-60Hz must be
supplied to the junction box of the fireplace in order for the
power vent to operate correctly.
WARNING
Risk of Fire!
• Power Vent must be paired to IFT-ACM before
installation is complete.
• If you have 120 VAC Power & Gas to applance:
- Immediately after connecting the PVI-WH
connector to the IFT-ACM, the IFT control
must be paired to recognize the Power Vent
as part of the control configuration.
- Appliance and Power Vent function must be
verified before installation is complete.
- Consult installation manuals for details.
• If you DO NOT have 120 VAC Power & Gas:
- DO NOT connect PVI-WH connector to IFT-
ACM.
- Disconnect 6V power to lock-out appliance.
Failure to follow instructions could result
in a fire or explosion.
23
Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP) Instructions • 4052-900 Rev. M• 09/17
Explosion
Hazard!
REMOVAL OF UNNECESSARY PARTS
Refer to Figure 4.6 for steps 1 through 4. Some features
may or may not exist on appliance. The shaded portion
corresponding to the numbered step is the task to be
performed.
1. Unplug control module power.
2. Remove and discard battery pack (if present).
3. Detach wires from 6 pin harness that connect an op-
tional appliance on/off control (if present) and discard.
4. Remove jumper/splitter wire (if present) and discard.