B. Installing Vent Cap
1. Remove the eight screws holding the back cover to the
cap. See Figure 3.6.
2. Slide the exhaust housing assembly out of the back of
the cap. See Figure 3.7 and 3.8.
3. Remove the four corrugated shipping pads. See Figure
3.9.
4. Install PVI wiring harness through the electrical access
hole in back cover cap. See Figure 3.10.
NOTE:
• The PVLP-SLP may be painted to a desired
color, as long as the paint selected has sufficient
temperature and environmental ratings.
• Thoroughly sand the existing coating prior to
painting with sand paper or steel wool.
• The front of the cap cover may be field-painted
and cured up to 400 degrees Fahrenheit (204°
C). All remaining parts of the cap may be
painted but they may not be cured beyond 190
degrees Fahrenheit (88° C) due to gaskets and
components overheating.
• Certain areas of the cap surface may reach up to
600 degrees Fahrenheit (316° C). Paints selected
should have sufficient temperature ratings.
• Cap contains silicone sealant which could affect
adherence of paint. Please advise local painter
of silicone content.