Hearth and Home Technologies PVLP-SLP Installation Instructions Manual page 14

Power vent low profile
Table of Contents

Advertisement

B. Installing Vent Cap (con't)
NOTE: Make sure there is no more than 4 or 5 inches
of wire extending through the back cap cover. See
Figure 3.11.
5. Attached the red and brown wires to the pressure switch.
See Figure 3.12.
6. Attach the white and black wires from the PVI harness
to the two black wires coming from the blower. Attach
the green wire from the PVI harness to the green/yellow
wire coming from the blower. See figure 3.13.
NOTE: After all wires are connected, the wire should look
like the picture in Figure 3.14.
7. The air baffle is shipped in the closed position; for cer-
tain vent runs the air baffle will need to be adjusted. To
adjust the baffle, remove the locking screw. See Figure
3.15. (Refer to section 5B to determine baffle setting.)
CAUTION! Risk of overheating! The baffle must re-
main fully closed when using PVLP-SLP with PRIMO
models. See installation instructions for details and
PRIMO48 exception.
8. To open the baffle, turn the adjustment bolt counter
clockwise. See Figure 3.16.
Figure 3.11
Figure 3.12
14
Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP) Instructions • 4052-900 Rev. M• 09/17
Figure 3.13
Figure 3.14
Figure 3.15
Figure 3.16

Advertisement

Table of Contents
loading