C. Pairing or Re-Pairing the IFT-RC400 to the
Electronic Control Module (IFT-ECM)
WARNING! After installation of Power Vent components,
the RC400 and IFT-ECM MUST BE Re-Paired for safe
operation.
CAUTION! Risk of Burns! DO NOT program the IFT
Remote Controls to the IFT-ECM when flame or cold
climate fuction is on or when appliance is hot.
1. On the IFT-ECM, move the ON/OFF/REMOTE switch to
the REMOTE position. The green LED will blink three
times. A few seconds later, an audible "beep" will occur
to indicate that the system is ready.
Note: If the green LED continues to blink slowly (system
is searching for a clear channel), wait until it stops before
proceeding to step 2.
2. Locate the pairing hole on the IFT-ECM. See Figure 4.11.
Using a paper clip or similar item, press and release the
pairing button. The IFT-ECM will "beep" once and the
green LED will blink for 14 seconds. During the 14
seconds, it is normal for installed accessories such as
lights, fan, and Power Vent to energize momentarily.
While the green LED on the IFT-ECM is blinking, tap
anywhere on the gray indicator bar located at the top of the
IFT-RC400 screen. Tap on the pairing function as shown in
Figure 4.12. If the IFT-RC400 has been paired successfully
to the IFT-ECM, a double audible 'beep" will be heard from
the IFT-ECM.
Note: If the RC400 displays the 'Now pairing remote to
product' display as shown below before able to reach the
diagnostic menu on remote, you must repeat the process
as follows;
A. Remove one battery from the RC400.
B. Press the pairing button on the IFT-ECM.
C. Quickly install the battery into the RC400.
D. As soon as the main screen appears, tap on the
RC400 gray indicator bar. Then immediately tap the
pairing icon. Successful pairing will be indicated by a
double beep from the IFT-ECM.
3. If the pairing is unsuccessful, repeat steps 1 & 2.
27
Hearth & Home Technologies • Power Vent Low Profile (PVLP-SLP) Instructions • 4052-900 Rev. M• 09/17
Note: If additional components are added such
as blowers, lights or Power Vent after initial
pairing, the pairing process must be repeated
again to detect additional components.
REMOTE POSITION
GREEN LED
Figure 4.11. Pairing IFT-ECM
Figure 4.12. IFT-RC400 Wall Mount / Pairing Screen
NOTE: Refer to Operating Guide and Troubleshoot-
ing Section of IFT-RC400 Installation Manual for
Operation and Maintenance Sections of Remote
Control.
PAIRING HOLE