Uwatec Xtender Instruction Manual page 46

Wrist dive computer
Hide thumbs Also See for Xtender:
Table of Contents

Advertisement

beyond the measureable range, the total dive time will be saved in the history
as 600 minutes.
• If the total number of dives has exceeded 999, then the counter rolls over from
999 back to 0 ¡ 1 and the data is saved.
• If the total dive time has exceeded 999 hours and 59 minutes, then the counter
rolls over from 999h59 to 0h00 ¡ 0h01 ¡ and the data is saved
(13) Out-of-range warning function (including warnings in the
decompression dive state)
• The following conditions exceed the measureable range of the dive computer
and cause an out-of-range warning display to appear and an audible alarm to
sound.
1. The depth exceeds the 99.9 m measurement limit ¡ bars appear in the
depth indicator
2. The dive time exceeds the 599 minute measurement limit ¡ bars
appear in the dive time indicator
3. Decompression becomes necessary at depths where the decompres-
sion stop depth exceeded 30 m (100 ft) ¡ decompression stop depth
displayed
4. The decompression stop time at the indicated decompression stop
depth
during a decompression dive exceeded 99 minutes, or the total ascent
time exceeded 99 minutes. ¡ bars appear in each time indicator
• Out-of-range warnings cause all display segments to flash.
• As soon as an out-of-range numeric value returns to within the measurement
range, the bars disappear and the measured value is indicated.
• An audible alarm sounds when a warning is issued, and the display segment
continues to flash until a surface interval of 48 hours has passed.
• Out-of-range warnings are saved in memory when they occur.
• If the E key goes OFF at a depth of 1.4 m or less, Dive mode cannot be
accessed even if the E key comes back ON. (An audible alarm sounds to
indicate that accessing Dive mode is prohibited.) However, if the C key and D
key are simultaneously pressed and held for approximately 15 seconds in Time