3.1.2 Mechanical ambient conditions

Storage
Vibration limits
Transport
Vibration limits
Shock limit values
Operation
Vibration limits
Pressure in the water cooler
Table 3:
Mechanical ambient conditions

3.1.3 chemical / mechanical active substances

Storage
Gases
Contamination
Solids
Transport
Gases
Contamination
Solids
Operation
Gases
Contamination
Solids
Table 4:
Chemical / mechanical active substances
26
Standard
EN 60721-3-1
1M1
Standard
EN 60721-3-2
2M1
EN 60721-3-2
2M1
Standard
EN 60721-3-3
3M1
EN 61800-5-1
Germ. Lloyd
EN 61373
Railway
Pressure
Standard
1C2
EN 60721-3-1
1S2
Standard
2C2
EN 60721-3-2
2S2
Standard
3C2
EN 60721-3-3
3S2
Particularities
Covered by 3M4
Particularities
Frequency 200...500 Hz, acceleration 15 m/s²
Free drop from 0.25 m
Particularities
Frequency 5...9 Hz, amplitude 6 mm
Frequency 9...200 Hz, acceleration 10 m/s²
Shock 11 ms, acceleration 100 m/s²
Frequency 10...57 Hz, amplitude ±0.075 mm
Frequency 57...150 Hz, acceleration 1 g
Frequency 5...13.2 Hz, amplitude 2 mm
Frequency 13.2...100 Hz, acceleration 0.7 g
Vibration Cat.1 - Class B
Shock 30 ms with 30...50 m/s²
Rated operating pressure: 10 bar
max. operating pressure: 10 bar
Particularities
Particularities
Particularities

Advertisement