3 Technical Data

3.1 Operating conditions

3.1.1 climatic ambient conditions

Storage
Surrounding temperature
Relative humidity
Storage height
Transport
Surrounding temperature
Relative humidity
Operation
Coolant inlet
Air
temperature
Water
Surrounding temperature
Relative humidity
Pollution degree
Version and degree of protec-
tion
Site altitude
Table 2:
Climatic ambient conditions
Standard
EN 60721-3-1
1K4
1K3
EN 60721-3-1
Standard
EN 60721-3-2
2K3
EN 60721-3-2
2K3
Standard
EN 60721-3-3
3K3
EN 60721-3-3
3K3
EN 60664-1
2
EN 60529
IP20
Particularities
-25...55 °C
5...95 % (without condensation)
Max. 3000 m above sea level
Particularities
-25...70 °C
95 % at 40 °C (without condensation)
Particularities
0...40 °C
5...40 °C
5...40 °C (extended to -10...45 °C)
From 45 °C to max. 55 °C a derating of 5 % per
1 K must be taken into consideration
5...85 % (without condensation)
Non-conductive pollution, occasional conden-
sation when PDS is out of service
Drive converter generally, except power con-
nections and fan unit (IPxxA)
Protection against foreign material > ø12.5 mm
No protection against water
max. 2000 m above sea level
With site altitudes over 1000 m a derating
of 1 % per 100 m must be taken into con-
sideration.
With site altitudes over 2000 m, the control
board to the mains has only basic isola-
tion. Additional measures must be carried
out when wiring the control system.