4 Mounting
Flow measurement with
Khafagi Venturi flume
26
3 ... 4 h
max
90°
2
Fig. 25: Flow measurement with rectangular overfall: d
the sensor (see chapter "Technical data"); h
spillway
1
Overflow orifice (side view)
2
Headwater
3
Tailwater
4
Overfall orifice (view from tailwater)
In general, the following points must be observed:
Install the sensor on the headwater side
Installation in the centre of the flume and vertical to the liquid
surface
Distance to the overfall orifice
Distance of orifice opening above ground
Min. distance of the orifice opening to tailwater
Min. distance of the sensor to max. storage level
Fig. 26: Flow measurement with Khafagi-Venturi flume: h
flume; B = tightest constriction in the flume
1
Position sensor
2
Venturi flume
In general, the following points must be observed:
Installation of the sensor at the inlet side
1
3
= max. filling of the rectangular
max.
3 ... 4 x h
max
90°
h
max
1
VEGAPULS 64 • HART and accumulator pack
90°
4
= min. distance of
min.
2
B
= max. filling of the
max.