Sign In
Upload
Manuals
Brands
Vega Manuals
Accessories
VEGAPULS 66
Vega VEGAPULS 66 Manuals
Manuals and User Guides for Vega VEGAPULS 66. We have
19
Vega VEGAPULS 66 manuals available for free PDF download: Operating Instructions Manual, Quick Setup Manual, Safety Manual
Vega VEGAPULS 66 Operating Instructions Manual (88 pages)
Profibus PA Radar sensor for continuous level measurement of liquids
Brand:
Vega
| Category:
Accessories
| Size: 3.9 MB
Table of Contents
Operating Instructions
1
Table of Contents
2
1 About this Document
4
Function
4
Target Group
4
Symbolism Used
4
2 For Your Safety
5
Authorised Personnel
5
Appropriate Use
5
Warning about Misuse
5
General Safety Instructions
5
CE Conformity
6
NAMUR Recommendations
6
Radio License for Europe
6
Radio License for Usa/Canada
6
Environmental Instructions
7
3 Product Description
8
Structure
8
Principle of Operation
9
Packaging, Transport and Storage
10
Accessories and Replacement Parts
10
4 Mounting
12
General Instructions
12
Instructions for Installation
12
5 Connecting to the Bus System
23
Preparing the Connection
23
Connect
24
Wiring Plan, Single Chamber Housing
25
Wiring Plan, Double Chamber Housing
26
Wiring Plan with Double Chamber Housing Ex D
27
Wiring Plan - Version IP 66/IP 68, 1 Bar
29
Set Instrument Address
29
Switch-On Phase
30
6 Set up with the Indicating and Adjustment Module
31
Insert Indicating and Adjustment Module
31
Adjustment System
33
Parameter Adjustment
34
Saving the Parameter Adjustment Data
47
7 Setup with Pactware
48
Connect the PC
48
Parameter Adjustment with Pactware
48
Saving the Parameter Adjustment Data
49
8 Set up with Other Systems
50
DD Adjustment Programs
50
9 Diagnosis, Asset Management and Service
51
Maintaining
51
Measured Value and Event Memory
51
Asset Management Function
52
Remove Interferences
56
Exchanging the Electronics Module
60
Software Update
60
How to Proceed in Case of Repair
61
10 Dismounting
62
Dismounting Steps
62
Disposal
62
11 Supplement
63
Technical Data
63
Supplement 11.1 Technical Data
63
Communication Profibus PA
72
Dimensions
78
Advertisement
Vega VEGAPULS 66 Operating Instructions Manual (84 pages)
Radar sensor for continuous level measurement of liquids
Brand:
Vega
| Category:
Accessories
| Size: 3.55 MB
Table of Contents
Table of Contents
2
1 About this Document
4
Function
4
Target Group
4
Symbols Used
4
2 For Your Safety
5
Authorised Personnel
5
Appropriate Use
5
Warning about Incorrect Use
5
General Safety Instructions
5
EU Conformity
6
NAMUR Recommendations
6
Radio License for Europe
6
Radio License for USA
6
Installation and Operation in the USA and Canada
7
Environmental Instructions
7
3 Product Description
8
Configuration
8
Principle of Operation
9
Packaging, Transport and Storage
9
Accessories and Replacement Parts
10
4 Mounting
12
General Instructions
12
Mounting Instructions
13
Measurement Setup - Pipes
17
5 Connecting to Power Supply
23
Preparing the Connection
23
Connecting
24
Wiring Plan, Single Chamber Housing
25
Wiring Plan, Double Chamber Housing
26
Wiring Plan, Ex-D-Ia Double Chamber Housing
28
Double Chamber Housing with VEGADIS-Adapter
29
Wiring Plan - Version IP 66/IP 68, 1 Bar
30
Switch-On Phase
30
6 Set up with the Display and Adjustment Module
31
Insert Display and Adjustment Module
31
Adjustment System
32
Measured Value Indication - Selection of National Language
33
Parameter Adjustment
34
Saving the Parameterisation Data
52
7 Setup with Pactware
53
Connect the PC
53
Parameter Adjustment with Pactware
53
Saving the Parameterisation Data
55
8 Set up with Other Systems
56
DD Adjustment Programs
56
Field Communicator 375, 475
56
9 Diagnosis, Asset Management and Service
57
Maintenance
57
Measured Value and Event Memory
57
Asset Management Function
58
Rectify Faults
61
Exchanging the Electronics Module
65
Software Update
65
How to Proceed if a Repair Is Necessary
66
10 Dismount
67
Dismounting Steps
67
Disposal
67
11 Supplement
68
Technical Data
68
Dimensions
76
Industrial Property Rights
82
Trademark
82
Vega VEGAPULS 66 Operating Instructions Manual (84 pages)
standpipe version Profibus PA sensor for continuous level measurement of liquids under arduous process conditions
Brand:
Vega
| Category:
Accessories
| Size: 1.23 MB
Table of Contents
Operating Instructions
1
Table of Contents
2
1 About this Document
5
Function
5
Target Group
5
Symbolism Used
5
2 For Your Safety
6
Authorised Personnel
6
Appropriate Use
6
Warning about Misuse
6
CE Conformity
6
Fulfilling NAMUR Recommendations
7
FCC and IC Conformity (Only for Usa/Canada)
7
Safety Instructions for Ex Areas
8
Manufacturer Declaration
8
Functional Range of Approved Instruments
9
Environmental Instructions
9
3 Product Description
11
Configuration
11
Principle of Operation
12
Operation
14
Storage and Transport
14
4 Mounting
15
General Instructions
15
Mounting Instructions
16
5 Connecting to Voltage Supply
18
Preparing the Connection
18
Connection Steps, Instrument Housing
19
Wiring Plan, Single Chamber Housing
20
Wiring Plan, Double Chamber Housing
22
Wiring Plan, Double Chamber Housing Exd
24
Wiring Plan, Version IP 66/IP 68, 1 Bar
26
Switch-On Phase
26
6 Setup with the Indicating and Adjustment Module PLICSCOM
27
Short Description
27
Insert the Indicating and Adjustment Module
27
PLICSCOM 6.1 Short Description
27
Adjustment System
29
Setup Procedure
30
Menu Schematic
39
Saving the Parameter Adjustment Data
42
7 Setup with Pactware™ and Other Adjustment Programs
43
Connecting the PC
43
Parameter Adjustment with Pactware
43
Parameter Adjustment with PDM
44
Saving the Parameter Adjustment Data
44
8 Maintenance and Fault Rectification
45
Maintenance
45
Remove Interferences
45
Exchange of the Electronics Module
47
Instrument Repair
48
9 Dismounting
49
Dismounting Steps
49
Disposal
49
10 Supplement
50
Technical Data
50
Profibus PA
58
Dimensions
79
Industrial Property Rights
81
Trademark
81
Advertisement
Vega VEGAPULS 66 Operating Instructions Manual (76 pages)
Radar sensor for continuous level measurement of liquids
Brand:
Vega
| Category:
Accessories
| Size: 4.69 MB
Table of Contents
Table of Contents
2
1 About this Document
4
Function
4
Target Group
4
Symbols Used
4
2 For Your Safety
5
Authorised Personnel
5
Appropriate Use
5
Warning about Incorrect Use
5
General Safety Instructions
5
EU Conformity
6
NAMUR Recommendations
6
Radio License for Europe
6
Radio License for USA
6
Radio License for Canada
7
Installation and Operation in the USA and Canada
8
Environmental Instructions
8
3 Product Description
9
Configuration
9
Principle of Operation
10
Packaging, Transport and Storage
11
Accessories and Replacement Parts
12
4 Mounting
14
General Instructions
14
Mounting Instructions
15
5 Connecting to Power Supply and Bus System
16
Preparing the Connection
16
Connecting
17
Wiring Plan, Double Chamber Housing
18
Double Chamber Housing with VEGADIS-Adapter
20
Switch-On Phase
20
6 Set up the Sensor with the Display and Adjustment Module
22
Adjustment Volume
22
Insert Display and Adjustment Module
22
Adjustment System
23
Measured Value Indication - Selection of National Language
24
Parameter Adjustment
25
Saving the Parameterisation Data
37
7 Setting up Sensor and Modbus Interface with Pactware
38
Connect the PC
38
Parameter Adjustment
39
Set Instrument Address
40
Saving the Parameterisation Data
41
8 Diagnosis, Asset Management and Service
42
Maintenance
42
Measured Value and Event Memory
42
Asset Management Function
43
Rectify Faults
46
Exchanging the Electronics Module
48
Software Update
49
How to Proceed if a Repair Is Necessary
49
9 Dismount
51
Dismounting Steps
51
Disposal
51
10 Supplement
52
Technical Data
52
Basics Modbus
58
Modbus Register
60
Modbus RTU Commands
62
Levelmaster Commands
65
Configuration Of Typical Modbus Hosts
68
Dimensions
70
Industrial Property Rights
72
Trademark
72
Vega VEGAPULS 66 Operating Instructions Manual (76 pages)
Radar sensor for continuous level measurement of liquids
Brand:
Vega
| Category:
Accessories
| Size: 1.88 MB
Table of Contents
Operating Instructions
1
Table of Contents
2
1 About this Document
4
Function
4
Target Group
4
Symbols Used
4
2 For Your Safety
5
Authorised Personnel
5
Appropriate Use
5
Warning about Incorrect Use
5
General Safety Instructions
5
CE Conformity
6
NAMUR Recommendations
6
Radio License for Europe
6
Radio License for Usa/Canada
7
Environmental Instructions
7
3 Product Description
8
Configuration
8
Principle of Operation
9
Packaging, Transport and Storage
9
Accessories and Replacement Parts
10
4 Mounting
12
General Instructions
12
Mounting 4.1 General Instructions
12
Mounting Instructions
13
5 Connecting to the Bus System
14
Preparing the Connection
14
Connecting
15
Wiring Plan, Single Chamber Housing
17
Wiring Plan, Double Chamber Housing
17
Wiring Plan, Double Chamber Housing Ex D Ia
19
Double Chamber Housing with DIS-ADAPT
20
Wiring Plan - Version IP 66/IP 68, 1 Bar
21
Set Instrument Address
21
Switch-On Phase
22
6 Set up with the Display and Adjustment Module
23
Insert Display and Adjustment Module
23
Adjustment System
24
Measured Value Indication - Selection National Language
25
Parameter Adjustment
26
Saving the Parameter Adjustment Data
45
7 Setup with Pactware
46
Connect the PC
46
Parameter Adjustment
46
Saving the Parameter Adjustment Data
47
8 Set up with Other Systems
48
DD Adjustment Programs
48
9 Diagnosis, Asset Management and Service
49
Maintenance
49
Measured Value and Event Memory
49
Asset Management Function
50
Rectify Faults
54
Exchanging the Electronics Module
56
Software Update
57
How to Proceed if a Repair Is Necessary
57
10 Dismount
58
Dismounting Steps
58
Disposal
58
Vega VEGAPULS 66 Operating Instructions Manual (76 pages)
Brand:
Vega
| Category:
Accessories
| Size: 3.59 MB
Table of Contents
Operating Instructions
1
Table of Contents
2
1 About this Document
4
Function
4
Target Group
4
Symbolism Used
4
2 For Your Safety
5
Authorised Personnel
5
Appropriate Use
5
Warning about Misuse
5
General Safety Instructions
5
CE Conformity
6
NAMUR Recommendations
6
Radio License for Europe
6
Radio License for Usa/Canada
6
Environmental Instructions
7
3 Product Description
8
Structure
8
Principle of Operation
9
Packaging, Transport and Storage
9
Accessories and Replacement Parts
10
4 Mounting
12
General Instructions
12
Instructions for Installation
13
5 Connecting to Power Supply
23
Preparing the Connection
23
Connect
24
Wiring Plan, Double Chamber Housing
25
Switch-On Phase
27
6 Setupwiththeindicatingandadjustmentmodule
28
Insert Indicating and Adjustment Module
28
Adjustment System
30
Parameter Adjustment
31
Saving the Parameter Adjustment Data
44
7 Setup with Pactware
45
Connect the PC
45
Parameter Adjustment with Pactware
46
Saving the Parameter Adjustment Data
47
8 Set up with Other Systems
48
DD Adjustment Programs
48
Communicator 375, 475
48
9 Diagnosis, Asset Management and Service
49
Maintaining
49
Measured Value and Event Memory
49
Asset Management Function
50
Remove Interferences
54
Exchanging the Electronics Module
58
Software Update
59
How to Proceed in Case of Repair
60
10 Dismounting
61
Dismounting Steps
61
Disposal
61
11 Supplement
62
Technical Data
62
Supplement 11.1 Technical Data
62
Dimensions
69
Vega VEGAPULS 66 Operating Instructions Manual (68 pages)
4...20 mA/HART - two-wire
Brand:
Vega
| Category:
Measuring Instruments
| Size: 2.85 MB
Table of Contents
Operating Instructions
1
Table of Contents
2
1 About this Document
4
Function
4
Target Group
4
Symbols Used
4
2 For Your Safety
5
Authorised Personnel
5
Appropriate Use
5
Warning about Incorrect Use
5
General Safety Instructions
5
Safety Label on the Instrument
6
EU Conformity
6
Fulfillment of NAMUR Recommendations
6
Radio License for Europe
6
FCC and IC Conformity (Only for Usa/Canada)
6
Installation and Operation in the USA and Canada
7
Environmental Instructions
7
3 Product Description
8
Configuration
8
Principle of Operation
9
Packaging, Transport and Storage
10
Accessories and Replacement Parts
11
4 Mounting
13
General Instructions
13
Mounting Instructions
15
5 Connecting to Power Supply
21
Preparing the Connection
21
Connection Procedure
22
Wiring Plan, Single Chamber Housing
23
Wiring Plan, Double Chamber Housing
25
Wiring Plan, Double Chamber Housing Ex D
27
Wiring Plan - Version IP 66/IP 68, 1 Bar
29
Switch-On Phase
29
6 Set up with the Display and Adjustment Module PLICSCOM
30
Short Description
30
Insert Display and Adjustment Module
30
Adjustment System
31
Setup Steps
32
Menu Schematic
44
Saving the Parameterisation Data
46
7 Set up with Pactware and Other Adjustment Programs
47
Connect the PC
47
Parameter Adjustment with Pactware
48
Parameter Adjustment with AMS™ and PDM
49
Saving the Parameterisation Data
50
8 Maintenance And Fault Rectification
51
Maintenance
51
Rectify Faults
51
Exchanging the Electronics Module
52
Software Update
52
How to Proceed if a Repair Is Necessary
53
9 Dismount
54
Dismounting Steps
54
Disposal
54
Supplement
55
Technical Data
55
Ambient Conditions
57
Dimensions
62
Industrial Property Rights
66
Trademark
66
Vega VEGAPULS 66 Operating Instructions Manual (68 pages)
Profibus PA, continuous level measurement of liquids under arduous process conditions
Brand:
Vega
| Category:
Accessories
| Size: 2.8 MB
Table of Contents
Operating Instructions
1
Table of Contents
2
1 About this Document
4
Function
4
Target Group
4
Symbols Used
4
2 For Your Safety
5
Authorised Personnel
5
Appropriate Use
5
Warning about Incorrect Use
5
General Safety Instructions
5
Safety Label on the Instrument
6
EU Conformity
6
Fulfillment of NAMUR Recommendations
6
Radio License for Europe
6
FCC and IC Conformity (Only for Usa/Canada)
6
Installation and Operation in the USA and Canada
7
Environmental Instructions
7
3 Product Description
8
Configuration
8
Principle of Operation
10
Packaging, Transport and Storage
10
Accessories and Replacement Parts
11
4 Mounting
13
General Instructions
13
Mounting Instructions
15
5 Connecting to Power Supply
21
Preparing the Connection
21
Connection Procedure
22
Wiring Plan, Single Chamber Housing
23
Wiring Plan, Double Chamber Housing
25
Wiring Plan, Double Chamber Housing Ex D
27
Wiring Plan - Version IP 66/IP 68, 1 Bar
29
Switch-On Phase
29
6 Set up with the Display and Adjustment Module PLICSCOM
30
Short Description
30
Insert Display and Adjustment Module
30
Adjustment System
31
Setup Steps
32
Menu Schematic
44
Saving the Parameterisation Data
46
7 Set up with Pactware and Other Adjustment Programs
47
Connect the PC Via VEGACONNECT
47
Parameter Adjustment with Pactware
48
Parameter Adjustment with PDM
49
Saving the Parameterisation Data
49
8 Maintenance And Fault Rectification
50
Maintenance
50
Rectify Faults
50
Exchanging the Electronics Module
51
Software Update
52
How to Proceed if a Repair Is Necessary
52
9 Dismount
53
Dismounting Steps
53
Disposal
53
Supplement
54
Technical Data
54
Profibus PA
60
Dimensions
64
Industrial Property Rights
66
Trademark
66
Vega VEGAPULS 66 Operating Instructions Manual (64 pages)
Radar sensor for continuous level measurement of liquids.
Brand:
Vega
| Category:
Measuring Instruments
| Size: 1.23 MB
Table of Contents
Operating Instructions
1
Table of Contents
2
1 About this Document
4
Function
4
Target Group
4
Symbolism Used
4
2 For Your Safety
5
Authorised Personnel
5
Appropriate Use
5
Warning about Incorrect Use
5
General Safety Instructions
5
CE Conformity
6
NAMUR Recommendations
6
Radio License for Europe
6
Radio License for Usa/Canada
6
Environmental Instructions
7
3 Product Description
8
Configuration
8
Principle of Operation
9
Packaging, Transport and Storage
10
Accessories and Replacement Parts
10
4 Mounting
13
General Instructions
13
Mounting Instructions
13
Mounting 4.1 General Instructions
13
5 Connecting to the Bus System
14
Preparing the Connection
14
Connecting
15
Wiring Plan, Single Chamber Housing
16
Wiring Plan, Double Chamber Housing
17
Wiring Plan, Double Chamber Housing Ex D Ia
19
Double Chamber Housing with DIS-ADAPT
20
Wiring Plan - Version IP 66/IP 68, 1 Bar
21
Set Instrument Address
21
Switch-On Phase
22
6 Set up with the Display and Adjustment Module
23
Insert Display and Adjustment Module
23
Adjustment System
24
Parameter Adjustment
25
Saving the Parameter Adjustment Data
33
7 Setup with Pactware
34
Connect the PC
34
Parameter Adjustment
34
Saving the Parameter Adjustment Data
35
8 Set up with Other Systems
36
DD Adjustment Programs
36
9 Diagnosis, Asset Management and Service
37
Maintenance
37
Measured Value and Event Memory
37
Asset Management Function
38
Rectify Faults
42
Exchanging the Electronics Module
44
Software Update
44
How to Proceed if a Repair Is Needed
45
10 Dismounting
46
Dismounting Steps
46
Disposal
46
11 Supplement
47
Technical Data
47
Ambient Conditions
50
Communication Profibus PA
53
Dimensions
58
Vega VEGAPULS 66 Operating Instructions Manual (68 pages)
4...20 mA/HART two-wire
Brand:
Vega
| Category:
Measuring Instruments
| Size: 2.73 MB
Table of Contents
Operating Instructions
1
Table of Contents
2
1 About this Document
4
Function
4
Target Group
4
Symbolism Used
4
2 For Your Safety
5
Authorised Personnel
5
Appropriate Use
5
Warning about Misuse
5
General Safety Instructions
5
Safety Label on the Instrument
6
CE Conformity
6
Fulfillment of NAMUR Recommendations
6
FCC and IC Conformity (Only for Usa/Canada)
6
Safety Instructions for Ex Areas
7
Environmental Instructions
7
3 Product Description
8
Configuration
8
Principle of Operation
9
Operation
10
Packaging, Transport and Storage
10
4 Mounting
12
General Instructions
12
Mounting 4.1 General Instructions
12
Mounting Instructions
14
5 Connecting to Power Supply
22
Preparing the Connection
22
Connection Procedure
23
Wiring Plan, Single Chamber Housing
24
Wiring Plan, Double Chamber Housing
26
Wiring Plan Double Chamber Housing Ex D
28
Wiring Plan - Version IP 66/IP 68, 1 Bar
30
Switch on Phase
30
6 Set up with the Indicating and Adjustment Module PLICSCOM
31
Short Description
31
Insert Indicating and Adjustment Module
31
Adjustment System
33
Setup Procedure
34
Menu Schematic
40
Saving the Parameter Adjustment Data
42
7 Setup with Pactware and Other Adjustment Programs
43
Connecting the PC
43
Parameter Adjustment with Pactware
44
Parameter Adjustment with AMS™ and PDM
45
Saving the Parameter Adjustment Data
45
8 Maintenance and Fault Rectification
46
Remove Interferences
46
Exchanging the Electronics Module
47
Software Update
48
Instrument Repair
48
9 Dismounting
50
Dismounting Steps
50
Disposal
50
Dismounting 9.1 Dismounting Steps
50
10 Supplement
51
Technical Data
51
Dimensions
59
Vega VEGAPULS 66 Operating Instructions Manual (64 pages)
standpipe version Foundation Fieldbus
Brand:
Vega
| Category:
Accessories
| Size: 1.14 MB
Table of Contents
Operating Instructions
1
Table of Contents
2
1 About this Document
5
Function
5
Target Group
5
Symbolism Used
5
2 For Your Safety
6
Authorised Personnel
6
Appropriate Use
6
Warning about Misuse
6
CE Conformity
6
Fulfilling NAMUR Recommendations
7
FCC and IC Conformity (Only for Usa/Canada)
7
Safety Instructions for Ex Areas
8
Manufacturer Declaration
8
Functional Range of Approved Instruments
9
Environmental Instructions
9
3 Product Description
11
Configuration
11
Principle of Operation
12
Operation
14
Storage and Transport
14
4 Mounting
15
General Instructions
15
Mounting Instructions
16
5 Connecting to Voltage Supply
18
Preparing the Connection
18
Connection Steps, Instrument Housing
19
Wiring Plan, Single Chamber Housing
20
Wiring Plan, Double Chamber Housing
22
Wiring Plan, Double Chamber Housing Exd
24
Wiring Plan, Version IP 66/IP 68, 1 Bar
26
Switch-On Phase
26
6 Setup with the Indicating and Adjustment Module PLICSCOM
27
Short Description
27
Insert the Indicating and Adjustment Module
27
PLICSCOM 6.1 Short Description
27
Adjustment System
29
Setup Procedure
30
Menu Schematic
36
Saving the Parameter Adjustment Data
38
7 Setup with Pactware™ and Other Adjustment Programs
39
Connecting the PC
39
Parameter Adjustment with Pactware
39
Parameter Adjustment with AMS
40
Saving the Parameter Adjustment Data
40
8 Maintenance and Fault Rectification
41
Maintenance
41
Remove Interferences
41
Exchange of the Electronics Module
43
Instrument Repair
43
9 Dismounting
45
Dismounting Steps
45
Disposal
45
10 Supplement
46
Technical Data
46
Foundation Fieldbus
53
Dimensions
58
Industrial Property Rights
60
Trademark
60
Vega VEGAPULS 66 Operating Instructions Manual (60 pages)
Foundation Fieldbus Standpipe version
Brand:
Vega
| Category:
Measuring Instruments
| Size: 2.42 MB
Table of Contents
Table of Contents
2
1 About this Document
4
Function
4
Target Group
4
Symbols Used
4
2 For Your Safety
5
Authorised Personnel
5
Appropriate Use
5
Warning about Incorrect Use
5
General Safety Instructions
5
Safety Label on the Instrument
6
EU Conformity
6
Fulfillment of NAMUR Recommendations
6
Radio License for Europe
6
FCC and IC Conformity (Only for Usa/Canada)
6
Installation and Operation in the USA and Canada
7
Environmental Instructions
7
3 Product Description
8
Configuration
8
Principle of Operation
10
Packaging, Transport and Storage
11
Accessories and Replacement Parts
11
4 Mounting
13
General Instructions
13
Mounting Instructions
15
5 Connecting to Power Supply
16
Preparing the Connection
16
Connection Procedure
17
Wiring Plan, Single Chamber Housing
18
Wiring Plan, Double Chamber Housing
19
Wiring Plan, Ex-D Double Chamber Housing
21
Wiring Plan - Version IP 66/IP 68, 1 Bar
23
Switch-On Phase
24
6 Set up with the Display and Adjustment Module PLICSCOM
25
Short Description
25
Insert Display and Adjustment Module
25
Adjustment System
26
Setup Steps
27
Menu Schematic
37
Saving the Parameterisation Data
39
7 Set up with Pactware and Other Adjustment Programs
40
Connect the PC
40
Parameter Adjustment with Pactware
41
Parameter Adjustment with AMS
42
Saving the Parameterisation Data
42
8 Maintenance And Fault Rectification
43
Maintenance
43
Rectify Faults
43
Exchanging the Electronics Module
44
Software Update
45
How to Proceed if a Repair Is Necessary
45
9 Dismount
46
Dismounting Steps
46
Disposal
46
Supplement
47
Technical Data
47
Foundation Fieldbus
52
Dimensions
56
Industrial Property Rights
59
Trademark
59
Vega VEGAPULS 66 Operating Instructions Manual (52 pages)
Standpipe version 4...20 mA/HART - two-wire
Brand:
Vega
| Category:
Accessories
| Size: 3.04 MB
Table of Contents
Operating Instructions
1
Table of Contents
2
1 About this Document
4
Function
4
Target Group
4
Symbols Used
4
2 For Your Safety
5
Authorised Personnel
5
Appropriate Use
5
Warning about Incorrect Use
5
General Safety Instructions
5
Safety Label on the Instrument
5
CE Conformity
6
Fulfillment of NAMUR Recommendations
6
FCC and IC Conformity (Only for Usa/Canada)
6
Safety Instructions for Ex Areas
6
Environmental Instructions
7
3 Product Description
8
Configuration
8
Principle of Operation
10
Operation
10
Packaging, Transport and Storage
11
4 Mounting
12
General Instructions
12
Mounting 4.1 General Instructions
12
Mounting Instructions
14
5 Connecting to Power Supply
15
Preparing the Connection
15
Connection Procedure
16
Wiring Plan, Single Chamber Housing
17
Wiring Plan, Double Chamber Housing
19
Wiring Plan, Double Chamber Housing Ex D
21
Wiring Plan - Version IP 66/IP 68, 1 Bar
23
Switch-On Phase
23
6 Set up with the Display and Adjustment Module PLICSCOM
24
Short Description
24
Insert Display and Adjustment Module
24
Adjustment System
25
Setup Steps
26
Menu Schematic
31
Basic Adjustment
32
Saving the Parameter Adjustment Data
33
7 Set up with Pactware and Other Adjustment Programs
34
Connect the PC
34
Parameter Adjustment with Pactware
35
Parameter Adjustment with AMS™ and PDM
36
Saving the Parameter Adjustment Data
37
Maintenance And Fault Rectification
38
Maintenance
38
VEGAPULS 66 Standpipe Version • 4
38
Rectify Faults
38
Exchanging the Electronics Module
39
Software Update
39
How to Proceed if a Repair Is Needed
40
9 Dismount
42
Dismounting Steps
42
Disposal
42
Dismount 9.1 Dismounting Steps
42
10 Supplement
43
Technical Data
43
Dimensions
49
Information
51
Vega VEGAPULS 66 Operating Instructions Manual (72 pages)
Profibus PA, sensor for continuous level measurement of liquids under arduous process conditions, suitable for applications in storage tanks
Brand:
Vega
| Category:
Accessories
| Size: 1.29 MB
Vega VEGAPULS 66 Quick Setup Manual (24 pages)
Radar sensor for continuous level measurement of liquids
Brand:
Vega
| Category:
Measuring Instruments
| Size: 1.63 MB
Table of Contents
Table of Contents
2
1 For Your Safety
3
Authorised Personnel
3
Appropriate Use
3
Warning about Incorrect Use
3
General Safety Instructions
3
EU Conformity
4
NAMUR Recommendations
4
Radio License for Europe
4
Radio License for USA
4
Environmental Instructions
5
2 Product Description
6
Configuration
6
3 Mounting
7
Mounting Instructions
7
4 Connecting to the Bus System
8
Connecting
8
Wiring Plan, Single Chamber Housing
9
Wiring Plan, Double Chamber Housing
9
5 Set up with the Display and Adjustment Module
11
Insert Display and Adjustment Module
11
Parameter Adjustment
12
Menu Overview
15
6 Set up with Smartphone/Tablet, Pc/Notebook Via Bluetooth
17
Preparations
17
Connecting
18
Sensor Parameter Adjustment
18
7 Supplement
20
Technical Data
20
Vega VEGAPULS 66 Quick Setup Manual (20 pages)
Foundation Fieldbus Radar sensor for continuous level measurement of liquids
Brand:
Vega
| Category:
Accessories
| Size: 1.2 MB
Table of Contents
Quick Setup Guide
1
Table of Contents
2
1 For Your Safety
3
Authorised Personnel
3
Appropriate Use
3
Warning about Incorrect Use
3
General Safety Instructions
3
EU Conformity
4
NAMUR Recommendations
4
Radio License for Europe
4
Radio License for USA
4
Environmental Instructions
5
2 Product Description
6
2.1 Configuration
6
3 Mounting
8
Mounting Instructions
8
4 Connecting to the Bus System
9
Connecting
9
Wiring Plan, Single Chamber Housing
10
Wiring Plan, Double Chamber Housing
10
5 Set up with the Display and Adjustment Module
11
Insert Display and Adjustment Module
11
Parameter Adjustment
12
Menu Overview
15
6 Supplement
17
Technical Data
17
Information
20
Vega VEGAPULS 66 Quick Setup Manual (20 pages)
Radar Sensor for Continuous Level Measurement of Liquids
Brand:
Vega
| Category:
Accessories
| Size: 1.37 MB
Table of Contents
Table of Contents
2
For Your Safety
3
Authorised Personnel
3
Appropriate Use
3
Warning about Incorrect Use
3
General Safety Instructions
3
EU Conformity
4
NAMUR Recommendations
4
Radio License for Europe
4
Radio License for USA
4
Environmental Instructions
5
Product Description
6
2.1 Configuration
6
Mounting
7
Mounting Instructions
7
Connecting to Power Supply
8
Connection of the Battery Charger
8
Wiring Plan
8
Set up with the Display and Adjustment Module
10
Insert Display and Adjustment Module
10
Parameter Adjustment
11
Menu Overview
14
Set up with Smartphone/Tablet, Pc/Notebook Via Bluetooth
16
Preparations
16
Connecting
17
Sensor Parameter Adjustment
17
Supplement
19
Technical Data
19
Vega VEGAPULS 66 Quick Setup Manual (20 pages)
Radar sensor for continuous level measurement of liquids, Modbus and Levelmaster protocol
Brand:
Vega
| Category:
Accessories
| Size: 1.41 MB
Table of Contents
Table of Contents
2
For Your Safety
3
Authorised Personnel
3
Appropriate Use
3
Warning about Incorrect Use
3
General Safety Instructions
3
EU Conformity
4
NAMUR Recommendations
4
Radio License for Europe
4
Radio License for USA
4
Environmental Instructions
5
Product Description
6
2.1 Configuration
6
Mounting
7
Mounting Instructions
7
Connecting to Power Supply and Bus System
8
Connecting
8
Wiring Plan
9
Set up the Sensor with the Display and Adjustment Module
11
Insert Display and Adjustment Module
11
Parameter Adjustment
11
Menu Overview
14
Set up with Smartphone/Tablet, Pc/Notebook Via Bluetooth
16
Preparations
16
Connecting
17
Sensor Parameter Adjustment
17
Supplement
19
Technical Data
19
Vega VEGAPULS 66 Safety Manual (16 pages)
VEGAPULS series 60 4...20 mA/HART
Brand:
Vega
| Category:
Measuring Instruments
| Size: 0.16 MB
Table of Contents
Table of Contents
2
Functional Safety
3
In General
3
Planning
5
Instrument Parameter Adjustment
7
Setup
9
Reaction During Operation and in Case of Failure
9
Recurring Function Test
9
Safety-Related Characteristics
10
Advertisement
Related Products
Vega VEGAPULS 64
Vega VEGAFLEX 61
Vega VEGAPULS 69
Vega VEGAPULS 67
Vega VEGAPULS 65
Vega VEGAPULS 68
Vega VEGAPULS 6X
Vega VEGAPULS WL 61
Vega VEGAPULS 61
Vega VEGAPULS 62
Vega Categories
Accessories
Measuring Instruments
Transmitter
Switch
Industrial Equipment
More Vega Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL