Reference plane
Inflowing medium
VEGAPULS 64 • HART and accumulator pack
Fig. 11: Mounting of the radar sensor on vessels with conical bottom
The measuring range of VEGAPULS 64 begins physically at the end
of the antenna. The min./max. adjustment, however, begins at the
reference plane. The reference plane is different depending on the
sensor version.
Plastic horn antenna: The reference plane is the sealing surface
on the lower edge
Thread with integrated horn antenna: The reference plane is
the sealing surface at the bottom of the hexagon
Flange with encapsulated antenna system: The reference
plane is the lower edge of the flange plating
Hygienic fittings: The reference plane is the highest contact point
between sensor process fitting and welded socket
The following graphic shows the position of the reference plane with
different sensor versions.
1
2
Fig. 12: Position of the reference plane
1
Reference plane
2
Plastic horn antenna
3
Threaded fittings
4
Flange connections
5
Hygienic fittings
Do not mount the instruments in or above the filling stream. Make sure
that you detect the product surface, not the inflowing product.
1
3
4
4 Mounting
1
1
5
19