4.1.3 Description of the LCD

4.1.3.1 Status Screens

DESCRIPTION
Load is protected by UPS power.
1
Load is supplied by inverter (Normal Operation)
and the batteries are connected and o.k.
Load is not protected by UPS power.
2
Load is supplied by mains power (load on
bypass) or it is supplied by the inverter (Normal
operation) and the batteries are not o.k.
3
Load not supplied.
UPS is switched off
To start the UPS press the two ON/OFF push
buttons simultaneously
The UPS is not supplying load anymore. The
4
output switch is open
NOTE:
On the right hand side of the LCD there is the indication of single /parallel UPS.
If the UPS is configured as single the indication will be "S"
If the UPS is configured as parallel the indication will be "P" followed by the UPS number
The max no. of module units are 20 per system.
EXEMPLES:
S
stands for Single UPS. The system consists of ONLY one UPS (e.g. Classic cabinet)
P01
stands for Parallel UPS in a Multi-UPS system and 01 stands for the first Module (MASTER)
in the Multi-UPS system.
P09
stands for Parallel UPS in a Multi-UPS system and 09 stands for the ninth Module (SLAVE)
in the Multi- UPS system.
P20
stands for Parallel UPS in a Multi-UPS system and 20 stands for the twentieth Module (SLAVE)
in the Multi- UPS system.
The configuration of the single / parallel UPS is achieved in the Menu "SET UP SERVICE". See Service Manual
section E.

4.1.3.2 Main Menu Screen

DESCRIPTION
1
Logging Control. A log of the last 64 events is
stored in the Power Management Display.
2
In Menu Measurements: monitor voltages,
power,frequencies, currents, autonomy etc.
3
The Command Menu enables to perform the
commands "Load to inverter", Load to bypass,
battery test.
4
The UPS Data are the UPS personalized
information "serial number"
5
Various settings can be performed by the user:
Date/Time, automatic battery test, etc.
6
Various adjustments can be performed by the
service staff
04-3008_S4_ABB_OPMCPDPA-S2_GB_121202
Printed in Switzerland – Modifications reserved
LCD-DISPLAY
LOAD
PROTECTED
LOAD
NOT PROTECTED
LOAD OFF
SUPPLY FAILURE
LOAD DISCONNECTED
PARALLEL SWITCH OPEN
LCD-DISPLAY
 EVENT LOG
MEASUREMENTS
 MEASUREMENTS
COMMANDS
 COMMANDS
UPS DATA
 UPS DATA
SET-UP USER
 SET-UP USER
SET-UP SERVICE
 SET-UP SERVICE
NO MORE MENU
Section-4
S
P01
P09
P20
Page 5/10 ABB