High Brightness precautions: Hazard Distance (HD)

HD
Hazard Distance (HD) is the distance measured from the projection lens at which the intensity or the energy per surface
unit becomes lower than the applicable exposure limit on the cornea or on the skin. The light beam is considered (to
be) unsafe for exposure if the distance from a person to the light source is less than the HD.
Restriction Zone (RZ) based on the HD
The HD depends on the amount of lumens produced by the projector and the type of lens installed. See next chapter"HD in function
of modifying optics", page 14.
To protect untrained end users (as cinema visitors, spectators) the installation shall comply with the following installation require-
ments: Operators shall control access to the beam within the hazard distance or install the product at the height that will prevent
spectators' eyes from being in the hazard distance. Radiation levels in excess of the limits will not be permitted at any point less than
2.0 meter (SH) above any surface upon which persons other than operators, performers, or employees are permitted to stand or less
than 1.0 meter (SH) lateral separation from any place where such persons are permitted to be. In environments where unrestrained
behavior is reasonably foreseeable, the minimum separation height should be greater than or equal to 3.0 meter to prevent potential
exposure, for example by an individual sitting on another individual's shoulders, within the HD.
These values are minimum values and are based on the guidance provided in IEC 62471-5:2015 section 6.6.5.
The installer must understand the risk and apply protective measures based upon the hazard distance as indicated on the label and
in the user information. Installation method, separation height, barriers, detection system or other applicable control measure shall
prevent hazardous eye access to the radiation within the hazard distance.
For example, projectors that have a HD greater than 1 m and emit light into an uncontrolled area where persons may be present
should be positioned in accordance with "the fixed projector installation" parameters, resulting in a HD that does not extend into
the audience area unless the beam is at least 2.0 meter above the floor level. In environments where unrestrained behavior is
reasonably foreseeable, the minimum separation height should be greater than or equal to 3.0 meter to prevent potential exposure,
for example by an individual sitting on another individual's shoulders, within the HD. Sufficiently large separation height may be
achieved by mounting the image projector on the ceiling or through the use of physical barriers.
For LIPs (Laser Illuminated Projectors) installed in the USA market the above limits do not apply. Lip's for installations other than in
cinema theaters shall be installed at a height vertically above the floor such that the bottom plane of the Hazard Zone shall be no
lower than 3 meters above the floor. Horizontal clearance to the hazard zone shall be 2.5 meters. Any human access horizontally
to the Hazard Zone, if applicable, shall be restricted by barriers. If human access is possible in an unsupervised environment, the
horizontal or vertical clearances shall be increased to prevent exposure to the RG3 hazard zone.
In addition for temporary installations (e.g.: rental and staging, lease, events ...) the following requirements apply:
This product can only be installed by Barco or sold or leased only to valid laser light show variance holders. In other words
our installers are required to have an approved laser light show variance. Such installers may currently hold a valid variance
for production of Class IIIb and IV laser light shows and/or for incorporation of the RG3 LIPs into their shows. Dealers and
distributors are also required to obtain a valid laser light show variance.
This product shall be located in such a way that all propagating beam paths within the Restriction Zone, and the audience can
be directly observed at all times.
Effects other than front or rear screen projections shall not be performed.
Communication shall be maintained with other personnel assisting in surveillance of the LIP projection.
In the event of any unsafe condition, immediately terminates (or designate the termination) of LIP projection light.
Install one or more readily accessible controls to immediately terminate LIP projection light. The power input at the projector side
is considered as a reliable disconnect device. When required to switch off the projector, disconnect the power cord at the projector
side. In case the power input at the projector side is not accessible (e.g. truss mount), the socket outlet supplying the projector shall
R5906753 DPXK BLP SERIES 20/11/2017
Label description
DISTANCE DE SECURITE : CONSULTER LE MANUEL
DE SECURITE
Hazard RG3: not for household use symbol
1. Safety
Label location
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp2k-17blpDp4k-17blpDp4k-36blpDp2k-23blpDp4k-23blp

Table of Contents