YASKAWA E7LVD002 Technical Manual page 137

Drive/bypass
Table of Contents

Advertisement

Specifications
50Hz
60Hz Saturation
50Hz Saturation
72Hz
Variable
Torque 1
50Hz
Variable
Torque 2
Variable
Torque 1
60Hz
Variable
Torque 2
If one of the custom V/f patterns is selected, then parameters E1-04 through E1-13 will determine the V/F pattern.
Table 5.9 is for 240V class units only, for 480V class units multiply the voltage values by 2.
When a factory Initialization is performed, the setting of E1-03 is unaffected but the settings of E1-04 through
IMPORTANT
E1-13 are returned to their factory default settings.
E1-04 Maximum Output Frequency
Setting Range:
0.0 to 120.0 Hz
Factory Default: 60.0 Hz
Table 5.9 Preset V/f Patterns
E1-03
V/f Pattern *1
(V)
230
0
0
17
10
(Hz)
0 1.3 2.5
50
(V)
1
230
F
2
1
F
17
2
10
(Hz)
0 1.5 3.0
50 60
(V)
230
3
3
17
10
(Hz)
0 1.5 3.0
60 72
(V)
4
230
5
57
4
40
5
10
9
(Hz)
0 1.3
25
50
(V)
6
230
7
57
6
40
7
10
9
(Hz)
0 1.5
30
60
Programming 5 - 45
Specifications
E1-03
High
Starting
8
Torque 1
50Hz
High
Starting
9
Torque 2
High
Starting
A
Torque 1
60Hz
High
Starting
B
Torque 2
90Hz
C
120Hz
D
V/f Pattern *1
(V)
230
9
8
28
22
15
13
(Hz)
0 1.3 2.5
50
(V)
230
B
A
28
22
17
13
(Hz)
0 1.5 3.0
60
(V)
230
C
17
10
(Hz)
0 1.5 3.0
60 90
(V)
230
D
17
10
(Hz)
0 1.5 3.0
60 120

Advertisement

Table of Contents
loading