BHT-1300B Series
Charging with the battery charger (CH-201A)
1.
Check the battery cartridge terminals and insert the
cartridge.
2.
Connect the power cable to the CH-201A and
connect the plug to a commercial AC power
source (230 V AC).
The LED will turn red when charging is commenced.
3.
The LED will turn OFF when charging is
complete.
Charging takes approximately 3 hours to charge the BT-20LB and 2 hours to charge the
Point
BT-130LA.
The time required for full-charge may be shortened for the battery of less discharged capacity.
The Indicator LED blinks in red under the conditions described below. You should take
appropriate measures.
・Abnormality detected in the battery cartridge temperature
Be sure to charge the BHT under environmental temperature of 0 to 40°C.
Do not use the battery cartridge in places exposed to excessively high temperatures or to direct
sunlight.
If no particular problem is found in the operating environments, stop charging and replace the
battery cartridge with a new one.
・Loose connection of the terminal
Wipe the dirt off the terminal. See Chapter 6.3 "Daily Maintenance".
・Battery cartridge broken or its product life expired
Replace the battery cartridge with a new one.
16
Terminals
LED red ON
OFF