Par. No.
Name
p1668
Current setpoint filter 3
denominator natural fre-
quency
Description: Sets the denominator natural frequency for current setpoint filter 3 (PT2, general filter).
Dependency: Current setpoint filter 3 is activated via p1656.2 and parameterized via p1668 ... p1671.
p1669
Current setpoint filter 3
denominator damping
Description: Sets the denominator damping for current setpoint filter 3.
Dependency: Current setpoint filter 3 is activated via p1656.2 and parameterized via p1668 ... p1671.
p1670
Current setpoint filter 3
numerator natural fre-
quency
Description: Sets the numerator natural frequency for current setpoint filter 3 (general filter).
Dependency: Current setpoint filter 3 is activated via p1656.2 and parameterized via p1668 ... p1671.
p1671
Current setpoint filter 3
numerator damping
Description: Sets the numerator damping for current setpoint filter 3.
Dependency: Current setpoint filter 3 is activated via p1656.2 and parameterized via p1668 ... p1671.
p1673
Current setpoint filter 4
denominator natural fre-
quency
Description: Sets the denominator natural frequency for current setpoint filter 4 (PT2, general filter).
Dependency: Current setpoint filter 4 is activated via p1656.3 and parameterized via p1673 ... p1675.
p1674
Current setpoint filter 4
denominator damping
Description: Sets the denominator damping for current setpoint filter 4.
Dependency: Current setpoint filter 4 is activated via p1656.3 and parameterized via p1673 ... p1675.
p1675
Current setpoint filter 4
numerator natural fre-
quency
Description: Sets the numerator natural frequency for current setpoint filter 4 (general filter).
Dependency: Current setpoint filter 4 is activated via p1656.3 and parameterized via p1673 ... p1675.
p1676
Current setpoint filter 4
numerator damping
Description: Sets the numerator damping for current setpoint filter 4.
Dependency: Current setpoint filter 4 is activated via p1656.3 and parameterized via p1673 ... p1675.
p2000
Reference speed
Description: Sets the reference quantity for speed and frequency.
All speeds or frequencies specified as relative value are referred to this reference quantity.
The reference quantity corresponds to 100% or 4000 hex (word) or 40000000 hex (double word).
Dependency: Refer to: p2003
p2002
Reference current
Description: Sets the reference quantity for currents.
All currents specified as relative value are referred to this reference quantity.
The reference quantity corresponds to 100% or 4000 hex (word) or 4000 0000 hex (double word).
Getting Started
A5E37208904-003, 04/2017
Min
Max
0.5
16000.0
0.001
10.000
0.5
16000.0
0.000
10.000
0.5
16000.0
0.001
10.000
0.5
16000.0
0.000
10.000
6.00
210000.00
0.10
100000.00
Factory
Unit
Data
Setting
type
1000.0
Hz
Float
0.300
-
Float
1000.0
Hz
Float
0.010
-
Float
1000.0
Hz
Float
0.300
-
Float
1000.0
Hz
Float
0.010
-
Float
3000.00 rpm
Float
100.00
Arm
Float
s
Effective
Can be
changed
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T
IM
T
91