Siemens SIMOTICS S-1FL6 Compact Operating Instructions page 100

Profinet pn interface
Hide thumbs Also See for SIMOTICS S-1FL6:
Table of Contents

Advertisement

Par. No.
Name
p8923[0...
PROFIdrive: Subnet
3]
mask of station
Description: Sets the subnet mask for the onboard PROFINET interface on the Control Unit.
The active subnet mask is displayed in r8933.
Note: The interface configuration (p8920 and following) is activated with p8925.
The parameter is not influenced by setting the factory setting.
p8925
PROFIdrive: Interface
configuration
Description: Setting to activate the interface configuration for the onboard PROFINET interface on the Control
Unit.
p8925 is automatically set to 0 at the end of the operation.
p8925 = 0: No function
p8925 = 2: Save and activate configuration
The interface configuration (p8920 and following) is saved and activated after the next POWER ON.
p29000 *
Motor ID
Description: Motor type number is printed on the motor rating plate as motor ID.
For a motor with an incremental encoder, users need to manually input the parameter value.
For a motor with an absolute encoder, the drive automatically reads the parameter value.
p29001
Reversal of motor direc-
tion
Description: Reversal of motor running direction. By default, CW is the positive direction while CCW the nega-
tive direction. After changing of p29001, reference point will lost, A7461 will remind user to referencing again.
0: No reversal
1: Reverse
p29002
BOP display selection
Description: Selection of BOP operating display.
0: Actual speed (default)
1: DC voltage
2: Actual torque
3: Actual position
4: Position following error
p29003
Control mode
Description: Selection of control mode.
1: Basic positioner control mode (EPOS)
2: Speed control mode (S)
p29005
Braking resistor capacity
percentage alarm thresh-
old
Description: Alarm triggering threshold for the capacity of the internal braking resistor.
Alarm number: A52901
p29006
Line supply voltage
Description: Nominal Line supply voltage, effective value of line to line voltage. Drive can operate within -15%
to +10% error.
For 400 V variant servo drive, the value range is 380 V to 480 V, default value is 400 V.
For 200 V variant servo drive, the value range is 200 V to 240 V, default value is 230 V.
100
Min
Max
0
255
0
3
0
65535
0
1
0
4
1
2
1
100
200
480
Factory
Unit
Data
Setting
type
0
-
U8
0
-
U8
0
-
U16
0
-
I16
0
-
I16
2
-
I16
100
%
Float
400/230 V
U16
Effective
Can be
changed
IM
T, U
IM
T, U
IM
T
IM
T
IM
T, U
IM
T
IM
T
IM
T
Getting Started
A5E37208904-003, 04/2017

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics v90

Table of Contents