Fault
Description
F7011
Motor overtemperature
F7085
Open-loop/closed-loop control parameters
changed
F7090
Drive: Upper torque limit less than the low-
er torque limit
F7093
Test signal error
F7220
Drive: Master control by the PLC missing
F7403
Lower DC link voltage threshold reached
F7404
Upper DC link voltage threshold reached
F7410
Current controller output limited
F7412
Commutation angle incorrect (motor model) F30021
F7442
LR: Multiturn does not match the modulo
range
F7443
Reference point coordinate not in the per-
mission range
F7450
Standstill monitoring has responded
F7451
Position monitoring has responded
F7452
Following error too high
F7453
Position actual value preprocessing error
F7458
EPOS: Reference cam not found
F7459
Zero mark not detected
F7460
EPOS: End of reference cam not found
F7464
EPOS: Traversing block is inconsistent
F7475
EPOS: Target position < start of traversing
range
F7476
EPOS: Target position > end of the travers-
ing range
F7481
EPOS: Axis position < software limit switch
minus
F7482
EPOS: Axis position > software limit switch
plus
F7484
EPOS: Fixed stop outside the monitoring
window
F7485
EPOS: Fixed stop not reached
F7488
EPOS: Relative positioning not possible
F7490
Enable signal withdrawn while traversing
F7491
STOP cam minus reached
Alarm list
Alarm
Description
A1009
Control module overtemperature
A1019
Writing to the removable data medium
unsuccessful
A1032
All parameters must be saved
A1045
Configuring data invalid
Getting Started
A5E37208904-003, 04/2017
Fault
Description
F8501
PROFIdrive: Setpoint timeout
F30001
Power unit: Overcurrent
F30002
DC link voltage, overvoltage
F30003
DC link voltage, undervoltage
F30004
Drive heat sink overtemperature
F30005
Power unit: Overload I
F30011
Line phase failure in main circuit
F30015
Phase failure motor cable
Ground fault
F30027
Precharging DC link time monitoring
F30036
Internal overtemperature
F30050
24 V supply overvoltage
F31100
Zero mark distance error
F31101
Zero mark failed
F31110
Serial communications error
F31111
Encoder 1: Absolute encoder internal error
F31112
Error bit set in the serial protocol
F31117
Inversion error signals A/B/R
F31130
Zero mark and position error from the coarse
synchronization
F31131
Encoder 1: Deviation position incremen-
tal/absolute too large
F31150
Initialization error
F52904
Control mode change
F52980
Absolute encoder motor changed
F52981
Absolute encoder motor mismatched
F52983
No encoder detected
F52984
Incremental encoder motor not configured
F52985
Absolute encoder motor wrong
F52987
Absolute encoder replaced
Alarm
Description
A7473
EPOS: Beginning of traversing range
reached
A7474
EPOS: End of traversing range reached
A7477
EPOS: Target position < software limit
switch minus
A7478
EPOS: Target position > software limit
switch plus