Adtech CNC Technology Co., Ltd.
020
axis control composite
Range
Unit
Authority
Default
Effective time
Note
021
additional panel enable
Range
Unit
Authority
Default
Effective time
Note
022
sys tool outlay enable
Range
Unit
Authority
Default
Effective time
Note
11.5 Tool magazine parameters (P4.)
001
Customized by manufacturer
Range
Unit
Authority
Default
Effective time
Note
- 72 -
:
0~1
:
None
:
Super user
:
ON/1
:
Instant
:
Used to configure whether the key for axis motion on the control panel is
enabled.
This parameter is used to shield the composite function of the key for axis
motion on the NC panel and reduce the possibility of misoperation when
additional panel is used. However, if no additional panel is used, this
parameter must be enabled, or else the axis motion can't be controlled
through the key.
:
0~1
:
None
:
Super user
:
OFF/0
:
Instant
:
Used to configure whether NC uses additional panel, which must be ADT
matching additional panel, or compatible with the interface of same
protocol.
If additional panel is used, the system testing info enable must be
deactivated (P3.19).
:
0~1
:
None
:
Super user
:
OFF/0
:
Instant
:
Used to configure the ATC function of the system, which is achieved by
calling out T_FUNC.NC or not.
:
:
:
Operation admin or higher
:
:
Instant
:
This parameter is determined by tool magazine design of each machine
tool manufacturer. Please refer to the machine too manuals for details.