Paper Instruction (PI) – Optional standard or inverted level EVFU or DVFU signal from the host
with the same timing and polarity as the data lines. PI line sensing is controlled by printer configura-
tion.
NOTE: The PI line must be disabled (configuration option selected from the control panel)
if the host computer does not drive or control the PI line. If the line is not controlled by the
host and sensing is enabled, rapid paper slewing will occur.
Interface Verification – Two pins on the interface connector jumpered together to verify proper in-
stallation of the interface connector.
Data Request
Pins not listed are not connected.

Dataproducts Parallel Interface Configuration

The printer is configured at the factory according to the specified interface. However, printer configu-
ration can be changed. The following configuration parameters can be verified or changed as neces-
sary to meet specific application requirements:
Data Bit 8 (enable or disable)
PI line (enable or disable)
Data Polarity (standard or inverted)
Response Polarity (standard or inverted)
7–2
Table 7–1. Connector Pin Assignments for
Dataproducts Interface with AMP Connector
OUTPUT
Signal
Pin
Ready
22
Return
6
On Line
21
Return
5
23
Return
7
I/F Verif.
45, 46
Paper Instr.
30
Return
14
INPUT
Signal
Pin
Data Line 1
19
Return
3
Data Line 2
20
Return
4
Data Line 3
1
Return
2
Data Line 4
41
Return
40
Data Line 5
34
Return
18
Data Line 6
43
Return
42
Data Line 7
36
Return
35
Data Line 8
28
Return
44
Data Strobe
38
Return
37
Interfaces