Line Feed - Printronix P3000 Series User's Reference Manual

P3000 series multifunction printer
Hide thumbs Also See for P3000 Series:
Table of Contents

Advertisement

Line Feed

P–Series/
Serial
Purpose
Comment
Programming
ASCII
LF
Prints the data in the buffer (if any) and advances the paper one line at the current
line space setting.
If configured for LF equals newline (LF=CR+LF), the logical print head is posi-
tioned at character column 1 of the new line. Otherwise, the logical print head does
not move when configured for LF function only (LF=LF ONLY). The LF function
cancels all single line print attributes such as double high (elongated) and double
wide (expanded) characters.
This code is always configured for LF=CR+LF in the P–Series protocol.
In the P–Series Even Dot Plot mode (high density graphics), the LF code does not
cause paper motion; the data in the buffer is plotted and the logical print head is posi-
tioned at character column 1 in anticipation of the Odd Dot Plot control code to com-
plete high density graphic plotting.
In the P–Series Odd Dot Plot mode (normal density graphics), the LF code plots the
data in the buffer, advances the paper a single dot row at the current vertical dot den-
sity, and positions the logical print head at character column 1.
Hex
0A
Decimal
10
6–45