Cleaning The Fixture - High End Systems intellaspot XT-1 User Manual

Table of Contents

Advertisement

CHAPTER 5
General Maintenance and Troubleshooting

Cleaning the Fixture

Lenses, Dichroics and Lithos
Warnings:To avoid electrical shock, disconnect power before servicing.
Equipment surfaces may reach temperatures up to 130° C (266° F).
Allow the fixture to cool before handling.
To clean the internal glass components:
1. Disconnect power to the fixture. If the fixture has been operating, allow the fixture to cool
before handling.
2. Remove the bezel by loosening the four captive screws on each side.
3. Clean the dichroics, lithopattern and effects, color wheels, and lens using a mild glass cleaner
(containing no ammonia) and a soft, lint-free cotton cloth.
4. All glass parts should be cleaned with using a mild glass cleaner (containing no ammonia) and
a soft, lint-free cotton cloth.
Filters
There are five washable
filters in intellaspot XT-1
fixtures. Two are behind
the intake vents on the
electronics housing. Two
are located on the inside of
one head cover and one on
the other head cover.
To clean the filter:
1. Remove the filter from
its location.
2. Wash with soap and
water.
3. Allow to dry and then
re-insert.
72
Bezel filters are located on the
inside of each cover over air
intakes.
A filter next to each handle
of the electronic housing
are easily removed from
the outside of the housing.
intellaspot
XT-1 User Manual
TM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents