Replacing Parts

WARNING: Disconnect power before servicing. Replace fuses with the
specified type and rating only.
Equipment surfaces may reach temperatures up to 130° C (266° F). Allow
the fixture to cool before handling.
Replacing Fuses
To replace a fuse:
1. Disconnect power to the fixture. If the fixture has been operating, allow the fixture to cool
before handling.
2. Use the following table to determine which fuse to replace and its location
Fuse
Module Link
2-phase motor driver boards
3-phase Pan and Tilt boards
Display Board
Battery
3. Replace the appropriate fuse(s) with a fuse of the same type and rating shown in the following
table.
Fuse
Module Link
Battery
2-phase driver boards
3-phase motor driver boards
Display board
Note:
(F2) on the Pan and Tilt boards has a spare fuse that can be used for any of
the motor driver boards.
60
Fuse Location
One fuse inside the electronics
housing on top of power supply.
Two fuses [F1] and [F2] on each
module driver board below the
connector.
[F1] on Tilt board in the head near
the fixture lens.
[F1] on Pan board in the electronic
housing behind the display panel
[F1] next to the Module Link header
On display board next to battery
Fuse Type and Rating
6.3A, 250 V, Slow Blow
1.5A, 125 V slow blow SMF
2.5 A, 125 V, Slow Blow SMF
Symptom of Failure
Fixture shuts down and will not receive
power.
Module motors will be off. Each fuse
protects two of the 4 motors associated with
each board. Board LEDs will remain on.
Pan or Tilt board-related motors and fans
will be off.
Display will not operate
Manufacturer
Littelfuse 326 015 or
Bussmann MDA-15
Order from High End
Systems
Littelfuse R454 02.5
intellaspot
HES p/n
90403019EF
90412029EF
90402024