Programming Procedure

(1)
To execute the fault logs/call logs collection, do the following programming.
START
CM0B
Provide the call log collection with the
VoIPDB.
NOTE:
Provide the fault log collection with the
VoIPDB.
CM12
Assign Service Restriction Class C to the
required stations.
CM15
Allow call log collection in Service Restriction
Class C assigned by CM12 Y=07.
NOTE:
Allow fault log collection in Service Restric-
tion Class C assigned by CM12 Y=07.
A
DESCRIPTION
When changing this data for
VoIPDB accommodated in a remote
unit, execute the system data copy
by CMEC Y=8 to the remote unit.
When changing this data for
VoIPDB accommodated in a remote
unit, execute the system data copy
by CMEC Y=8 to the remote unit.
Chapter 1 MAINTENANCE SERVICES
Y=2XX (VOIP Port [2] + Unit No. [01-50])
(1)
90
(2)
0 : To provide
1 : Not provided
Y=2XX (VOIP Port [2] + Unit No. [01-50])
(1)
91
(2)
0 : Not provided
1 : To provide
Y=07
(1)
X-XXXXXXXX: IP Station No.
(2)
00-15 : Service Restriction Class C
Y=194
(1)
00-15: Service Restriction Class C assigned
by CM12 Y=07
(2)
0 : Allow
1 : Restricted
Y=195
(1)
00-15: Service Restriction Class C assigned
by CM12 Y=07
(2)
0 : Restricted
1 : Allow
1-42
VoIP LOG COLLECTION
DATA