95Ch2001.Fm April/16/2010 - NEC UNIVERGE SV8300 System Maintenance Manual

Ip pbx
Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

C
After dialing the first digit, Dial
Tone from the distant office is not
disconnected.
END
CHECK
(1)
Appropriate signal (DP/DTMF) to distant
office is transmitted.
• System Data Programming for DP
signal: CM35 Y=001, 013, 023, 025
• System Data Programming for DTMF
signal: CM35 Y=001, 013, 024, 026, 046
(2)
System Data Programming for Numbering
Plan: CM20 Y=0-3: A100-A163,
CM20 Y=0-3: A230-A231,
CM22, CM23
REPLACE
(1)
Trunk blade
(2)
CPU blade
2-45