BLADE
LED STATUS
NAME
CD-CCTA
LIVE LED is not
(CCT)
flashing at 120
IPM
CD-4LCA/
LIVE LED is not
8LCA (LC)
flashing at 120
IPM
CD-8DLCA/
LIVE LED is not
16DLCA
flashing at 120
(DLC)
IPM
CD-4CSIB
LIVE LED is not
(CSI)
flashing at 120
IPM
CD-4CSIB-A
LIVE LED is not
(CSI)
flashing at 120
IPM
Remedial Action on Each LED Status
FAULT
CONTENT
Abnormal operation of
CCT blade
Abnormal operation of
LC blade
Abnormal operation of
DLC blade
Abnormal operation of
CSI blade
Abnormal operation of
CSI blade
2-36
Chapter 2 TROUBLESHOOTING
FAULT INFORMATION DISPLAY
REMEDIAL ACTION
Confirm the programming data:
1
CM05 Y=0.
Check to see if the cable is correctly
2
connected.
If the fault cannot be cleared,
3
replace the blade.
Confirm the programming data:
1
CM05 Y=0.
Check to see if the cable is correctly
2
connected.
If the fault cannot be cleared,
3
replace the blade.
Confirm the programming data:
1
CM05 Y=0.
Check to see if the cable is correctly
2
connected.
If the fault cannot be cleared,
3
replace the blade.
Confirm the programming data:
1
CM05 Y=0.
Check to see if the cable is correctly
2
connected.
If the fault cannot be cleared,
3
replace the blade.
Confirm the programming data:
1
CM05 Y=0.
Check to see if the cable is correctly
2
connected.
If the fault cannot be cleared,
3
replace the blade.