NEC UNIVERGE SV8300 System Maintenance Manual page 100

Ip pbx
Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

Line Status and Remedial Action for Hardware Test
INDICATED
DATA
06
DLC blade down
08
Line failure detect
• IP STATION
INDICATED
DATA
00
Terminal is not connected
01
Terminal is connected
Line Status and Remedial Action for Software Test
• SINGLE LINE TELEPHONE/MULTILINE TERMINAL
INDICATED
DATA
01
Idle
02
Line Lockout
Other than
Busy
01, 02
LINE STATUS
LINE STATUS
LINE STATUS
REMEDIAL ACTION
Replace the blade with a known good one and check to
see if the same failure occurs.
Replace the terminal with a known good one and check
to see if the same failure occurs.
REMEDIAL ACTION
Check the LAN cable connection between the ter-
1
minal and the PBX.
Check the condition of LAN cable connection by
2
transmitting the ping packet.
Confirm the condition of the LAN device (such as
3
power of the HUB) connected to the VoIPDB.
No action is required.
REMEDIAL ACTION
No action is required.
Place the handset of the station in line lockout back
onto the hookswitch.
No action is required.
2-32
Chapter 2 TROUBLESHOOTING
FAULT INFORMATION DISPLAY
NWA-033627-001 Rev.4.0
95ch2001.fm

Advertisement

Table of Contents
loading

Table of Contents