FAULT
FAULT
KIND
CONTENT
NUMBER
way Channel
for data com-
munication
10E
Illegal use of
CPU blade for
Remote Unit
only
110
Communica-
tion error
occurrence
between active
CPU and stand
by CPU
112
Chassis (2U)
failure
116
All blades
lockup in
FAULT INFORMATION
Fault Content: Fault detection by a
health check
Fault Content: Stand by CPU down
2-29
Confirm if the highway chan-
nel for ISDN communication
is correctly set (CM05 Y=2).
Replace the blade for SV8300.
Check the stand by CPU for
abnormal conditions.
Replace the Expansion Chassis
(2U) with a new one.
1
cable is correctly con-
nected to the Expansion
Chassis (2U).
Check the condition of the
2
BUS cards of the Control-
ling Chassis (1U) and the

Expansion Chassis (2U),

and replace with a new
one if necessary.
Replace the Expansion
3
Chassis (2U) with a new
one.