NEC UNIVERGE SV8300 System Maintenance Manual page 95

Ip pbx
Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

FAULT
FAULT
KIND
CONTENT
NUMBER
04A
Long call
duration infor-
mation
061
VoIPDB
Startup
Process
is failure
100
Power failure
102
DTI line failure [PRI]
Remedial Action on Each Fault Kind
FAULT INFORMATION
Connection Status: Call from a station
Connection Status: Termination to sta-
Connection Status: Call with tandem
Connection Status: Termination with
FAN
AC input failure
JACK insertion condition
Power Off
Battery
1U/2U info
FTDK: 4
[BRI/CCT]
FTDK: 3
FTDK: 4
FTDK: 5
[DTI]
FTDK: 15
2-27
Chapter 2 TROUBLESHOOTING
tion
connection
tandem connection
Check to see if the FAN cable
is correctly connected.
Check to see if the AC power
source is cut off or the plug is
disconnected.
Check to see if the Battery
cable is correctly connected.
Check to see if the MDF
cable is correctly connected.
FAULT INFORMATION DISPLAY
REMEDIAL ACTION
Confirm the call status of
1
the terminal.
Disconnect the call when
2
the line is not released.