Operating Procedure - NEC UNIVERGE SV8300 System Maintenance Manual

Ip pbx
Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

Operating Procedure

(1)
To disconnect the battery
ST
COMMAND=
EC0
+
DE
EC0>
00
+
DE
EC0>00:1 –
0
+
EXE
EC0>00:1 – 0
OK
(2)
To reconnect the battery
ST
COMMAND=
DE
EC0>
EC0
+
DE
EC0>00:0 –
00
+
1
+
EXE
EC0>00:0 – 1
OK
Chapter 1 MAINTENANCE SERVICES
For the first data, specify the desired unit (01 to 50)
whose battery is to be disconnected. To specify
Unit 01,02,03 and 04 collectively, enter 00.
When the first data is entered, the current status of the
specified unit is displayed. (1: Normal operation)
Enter 0 for the second data to disconnect.
For the first data, specify the desired unit (01 to 50)
whose battery is to be reconnected. To specify
Unit 01,02,03 and 04 collectively, enter 00.
When the first data is entered, the current status of the
specified unit is displayed. (0: Battery released)
Enter 1 for the second data to reconnect.
1-19
BATTERY RELEASE CONTROL
NWA-033627-001 Rev.4.0
95ch1001.fm
APRIL/16/2010