FAULT
FAULT
KIND
CONTENT
NUMBER
001
System Reset
012
CS/ZT fault
Remedial Action on Each Fault Kind
FAULT INFORMATION
Reset kind: SENSE switch was
changed to 0
Reset kind: Serious failure 7
Reset kind: Reset by CAT or PCPro
Changeover of Dual CPU System
Fault Kind Details: Fault notice from
Fault Kind Details: CS/ZT reset failure
Fault Kind Details: CS/ZT condition
Fault Kind Details: CS/ZT condition
Fault Kind Details: B channel condi-
Fault Kind Details: SYS-ID upload
2-17
Chapter 2 TROUBLESHOOTING
No specific action is required.
Replace the CPU blade.
No specific action is required.
No specific action is required.
No specific action is required.
CS/ZT
read failure
No specific action is required.
unmatched
No specific action is required.
tion unmatched
failure
FAULT INFORMATION DISPLAY
REMEDIAL ACTION
Make the CS/ZT busy or
1
idle condition by CME5
Y=3.
Turn OFF and ON the
2
CS/ZT power switch.
Check the CS/ZT with
1
SYS-ID is correct by
CMAE Y=00>09.
Make the CS/ZT busy or
2
idle condition by CME5
Y=3.
Turn OFF and ON the
3
CS/ZT power switch.
Continued on next page
NWA-033627-001 Rev.4.0
95ch2001.fm