NEC UNIVERGE SV8300 System Maintenance Manual page 47

Ip pbx
Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

NOTE:
To use Hyper Terminal, select File
• To collect the fault logs and call logs, be sure to set the CPU blade to on-line mode (set SENSE
switch to 0-4).
(2)
Conditions of fault log collection
• By collecting fault logs, you can specify the reset causes and reset time.
• By collecting fault logs, you can calculate the number of sending control packets, the number of
re-sending control packets, the number of failed re-sending control packets, the number of
received control packets, the received error control packets, and the error number of control
sequences.
• The fault logs are collected by the following timing.
- When IP Stations login to the system, and when the VoIPDB is in online status
- When you set the system data for fault logs collection (CMEA Y=6>11) from PCPro/CAT
• The output format of fault logs is as follows.
STN31100 08/04/30 12:48:19
1
2
DATA=1:RESET CAUSE
1=06440755 08/04/25 17:38:35
3=06440755 08/04/25 18:26:06
5=06440755 08/04/28 14:50:03
7=06440755 08/04/28 20:26:53
3
4
DATA=2:CONTROL PACKET COUNTER (PROTOCOL=2)
1=000016AD
2=000016AD
5=000016A6
6=00000C0A
3
7
DATA=3:REGISTRATION NG
1=FF-DRS0
2=FF-DRS0
5=FF-DRS1
6=FF-DRS1
3
8
TIME OUT
9
2=06440755 08/04/25 18:23:19
4=06440755 08/04/28 10:34:17
6=06440755 08/04/28 16:23:48
8=06440755 08/04/30 12:48:03
5
3
4
6
3=00000008
7=00000000
3=FF-DRS0
4=FF-DRS1
7=FF-DRS2
8=FF-DRS2
Chapter 1 MAINTENANCE SERVICES
Properties, and set emulation to VT100.
5
4=00000001
1-35
VoIP LOG COLLECTION
NWA-033627-001 Rev.4.0
95ch1001.fm