Programming Procedure

(1)
To set a periodic maintenance reminder, do the following programming:
START
CM43
Assign the date and time setting for periodic
maintenance.
Assign the check item for periodic mainte-
nance.
CM51
Specify the Multiline Terminal for alarm
display, if required.
CM90
Assign the alarm indication key to Multiline
Terminal function key, if required.
CMEA
Set the alarm kind for periodic maintenance.
END
(2)
To clear the alarm, do the following programming:
START
CMEA
Clear external alarms.
END
DESCRIPTION
DESCRIPTION
Chapter 1 MAINTENANCE SERVICES
Y=2
(1)
00-07
Periodic maintenance
:
(2)
YYYY MM DD HH
YYYY: 2010-2099 (Year)
MM
: 01-12 (Month)
DD
: 01-31 (Date)
HH
: 00-23 (Hour)
Y=3
(1)
00-07
Periodic maintenance
:
(2)
0 : Battery check
1-7: Check item No. 1-No. 7
Y=16
(1)
01: Multiline Terminal No. 1
02: Multiline Terminal No. 2
(2)
X-XXXXXXXX: My line number of
Y=00
(1)
My Line No. +
(2)
F5020: Alarm display
Y=2
(1)
016
(2)
1: MN alarm
2: MJ alarm
Y=1
(1)
00
: Clear all of MJ/MN/-- alarms
(2)
CCC: Alarm clear
1-30
FAULT REPORT SCHEDULING
DATA
Multiline Terminal
,
+Key No.
DATA
NWA-033627-001 Rev.4.0