Fault Information Display; Remedial Action - NEC UNIVERGE SV8300 System Maintenance Manual

Ip pbx
Hide thumbs Also See for UNIVERGE SV8300:
Table of Contents

Advertisement

Line Status and Remedial Action for Hardware Test
• SINGLE LINE TELEPHONE
INDICATED
DATA
00
Blade is not mounted/
initialized
01
Normal Operation of blade No action is required.
02
03
04
05
• DIGITAL MULTILINE TERMINAL
INDICATED
DATA
00
Terminal is not connected
or Tip wire is grounded
01
Terminal is connected
02
Short circuit is made on the
line
03
Ring wire is grounded
04
DLC blade is not mounted
05
Terminal failure
LINE STATUS
LINE STATUS

REMEDIAL ACTION

Check the cable connection between the terminal
1
and the PBX.
Check to see if the cable is cut off.
2
Check to see if a short circuit exists on the line.
Check to see if the Ring wire of the cable is grounded.
Check to see if the LC blade is properly mounted.
No action is required.
REMEDIAL ACTION
Check the cable connection between the terminal
1
and the PBX.
Check to see if the cable is cut off.
2
Check to see if the Tip wire of the cable is
3
grounded.
No action is required.
Check to see if a short circuit exists on the line.
Check to see if the Ring wire of the cable is grounded.
Check to see if the DLC blade is properly mounted.
Replace the terminal with a known good one and check
to see if the same failure occurs.
2-31
Chapter 2 TROUBLESHOOTING

FAULT INFORMATION DISPLAY

Continued on next page
NWA-033627-001 Rev.4.0
95ch2001.fm
JULY/17/2009