Setup With The Indicating And Adjustment Module Plicscom; Short Description; Installing The Indicating And Adjustment Module Plicscom; Plicscom 6.1 Short Description - Vega VEGABAR 53 Operating Instructions Manual

Pressure transmitter
Hide thumbs Also See for VEGABAR 53:
Table of Contents

Advertisement

Setup with the indicating and adjustment module PLICSCOM

Function/Configuration
Insert/remove PLICSCOM
20
6 Setup with the indicating and
adjustment module PLICSCOM

6.1 Short description

The indicating and adjustment module PLICSCOM is used for
measured value display, adjustment and diagnosis. It can be
mounted in the following housing versions and instruments:
All sensors of the plics
l
well as in the double chamber housing (optionally in the
electronics or connection compartment)
External indicating and adjustment unit VEGADIS 61.
l
Note:
You will find detailed information on the adjustment in the
operating instructions manual of the indicating and adjustment
module PLICSCOM.
6.2 Installing the indicating and adjustment
module PLICSCOM
PLICSCOM can be inserted or removed at any time. It is not
necessary to interrupt the power supply.
To mount, proceed as follows:
1 Unscrew the housing cover
2 Place PLICSCOM in the desired position on the electronics
(you can choose any one of four different positions - each
displaced by 90°)
3 Press PLICSCOM lightly onto the electronics and turn it to
the right until it snaps in.
4 Screw housing cover with inspection window tightly back
on
Removal is carried out in reverse order.
PLICSCOM is powered by the sensor, an additional con-
nection is not necessary.
®