Vega VEGABAR 53 Operating Instructions Manual page 42

Pressure transmitter
Hide thumbs Also See for VEGABAR 53:
Table of Contents

Advertisement

Supplement
Input variable
Adjustment range of the adjustment:
- zero/Min
- span/Max
Recommended max. turn down
Nominal range
Gauge pressure
0...0.4 bar/0...40 kPa
0...1.6 bar/0...160 kPa
0...40 bar/0...4 MPa
0...100 bar/0...10 MPa
0...250 bar/0...25 MPa
0...600 bar/0...60 MPa
-1...3 bar/-100...300 kPa
-1...5 bar/-100...500 kPa
-1...15 bar/-100...1.5 MPa
Absolute pressure
0...0.4 bar/0....0 kPa
0...1.6 bar/0...160 kPa
0...6.0 bar/0...600 kPa
0...16.0 bar/0...16 MPa
Reference conditions and influencing variables (similar to DIN EN 60770-1)
Reference conditions acc. to DIN EN 61298-1
- Temperature
- Relative humidity
- Atmospheric pressure
Determination of characteristics
Characteristic
Calibration position
Influence of the installation position
42
-5 ... +95 % of the nominal measuring range
-5 ... +105 % of the nominal measuring range
1:30 (no limitation)
Overload resistance
2 bar/200 kPa
10 bar/1.000 kPa
80 bar/8 MPa
200 bar/20 MPa
500 bar/50 MPa
1,200 bar/120 MPa
17 bar/1.700 kPa
35 bar/3500 kPa
80 bar/8 MPa
2 bar/20000 kPa
10 bar/1.000 kPa
35 bar/3500 kPa
80 bar/8 MPa
18 ... 30°C (64.4 ... 86°F)
45 ... 75 %
860 ... 1060 mbar (86 ... 106 kPa/
12.5 ... 15.4 psi)
limit point adjustment acc. to DIN 16086
Linear
upright, diaphragm points downward
depending on the isolating diaphragm version
Vacuum resistance
0 bar/0 kPa
0 bar/0 kPa
0 bar/0 kPa
0 bar/0 kPa
0 bar/0 kPa
0 bar/0 kPa
-1.0 bar/-100 kPa
-1.0 bar/-100 kPa
-1.0 bar/-100 kPa
VEGABAR 53 - Profibus PA