6 Set up with the indicating and adjustment module PLICSCOM

6 Set up with the indicating and adjustment
module PLICSCOM

6.1 Short description

The indicating and adjustment module is used for measured value
display, adjustment and diagnosis. It can be mounted in the following
housing versions and instruments:
All continuously measuring sensors in single as well as double
l
chamber housing (optionally in the electronics or connection
compartment)
External indicating and adjustment unit
l
Note:
You can find detailed information on the adjustment in the operating
instructions manual "Indicating and adjustment module".

6.2 Insert indicating and adjustment module

The indicating and adjustment module can be inserted into the sensor
and removed again at any time. It is not necessary to interrupt the
power supply.
Proceed as follows:
Unscrew the housing cover
1
Place the indicating and adjustment module in the desired position
2
on the electronics (you can choose any one of four different
positions - each displaced by 90°)
Press the indicating and adjustment module onto the electronics
3
and turn it to the right until it snaps in.
Screw housing cover with inspection window tightly back on
4
Removal is carried out in reverse order.
The indicating and adjustment module is powered by the sensor, an
additional connection is not necessary.