Check Points on Completion of Repair

■ After repair works have finished, check the insulation resistance between live part
(power plug) and dead metal part (earth) and make sure it is 10M and above.
Failure to check the insulation resistance could result in accident on customer due to
leakage current and electrical shock.
Check the
insulation resistance
■ Use an exclusive AC outlet for power supply.
Different voltage or rating could result in fire or electrical shock. If a power outlet is
shared with other appliance, the outlet may abnormally heat up and cause fire.
Use exclusive
power outlet
■ Connect earth wire.
Failure to connect earth wire could result in electrical shock in case of leakage current.
Consult electrician or your dealer for earth wire.
Connect earth wire
■ Do not install the machine in a bathroom or a place where is exposed to rain.
Failure to observe this warning could result in electrical shock or fire due to leakage
current.
No using in
wet place
■ Wipe off the dusts accumulated on the metal parts of the power plug or their mounted
surface.
Accumulated dust could result in fire.
Remove dusts
■ Before laundry, turn on the tap and make sure that the connection of the water supply
hose is not loosened and no water leaks from there.
Loosened screw or hose connection could result in unexpected accident due to water
leakage.
Check water
leakage